OptiFiber® Pro OTDR Family
Product Highlights
Makes novices into experts and experts faster
- Multiple wavelengths (850, 1300, 1310,1490, 1550 and 1625 nm) support LAN, datacenters, PON, FTTx and outside plant applications.
- Automated setup senses fiber characteristics and sets measurement parameters
- Manual Expert mode allows simple adjustments to automated settings for detailed testing.
- EventMap automatically identifies events including connectors, splices, bends, and splitters
- Gesture-based interface allows fast, in-depth trace analysis View More >
- SmartLoop™ OTDR technology tests two fibers in a single test eliminating the need to travel to the far end of the connection to perform tests.
- Instantaneous on-board bi-directional averaging results included as standard
- Integrates with LinkWare™ Live to manage jobs and testers from any smart device.
- Future-ready VersivTM design supports copper certification to Category 8, fiber loss and inspection.
PRODUCT NAVIGATION
Overview
Designed for Enterprise, Datacenter, Outside Plant and PON Fiber
As fiber networks evolve, the need to test in more locations has increased. OTDRs are now needed for:
- FTTx
- Enterprise
- OSP
- PON
- POLAN
Many OTDRs designed for fiber troubleshooting are designed for carrier and contain cumbersome and complicated features. The OptiFiber Pro OTDR family is the first class of OTDRs that is built with features and usability for both the enterprise network engineers, and cable installers working in both enterprise and OSP environments.
Features
Models & Accessories
Models
OFP2-100-M-NW Gold Support
GLD-OFP-100-M
1 year of Gold Support for OFP2-100-M, OFP2-100-M-NW, OFP-100-M-W or OFP-100-M
GLD3-OFP-100-M
3 years of Gold Support for for OFP2-100-M, OFP2-100-M-NW, OFP-100-M-W or OFP-100-M
OFP2-100-S-NW Gold Support
GLD-OFP-100-S
1 year of Gold Support for OFP2-100-S, OFP2-100-S-NW, OFP-100-S-W or OFP-100-S
GLD3-OFP-100-S
3 years of Gold Support for OFP2-100-S, OFP2-100-S-NW, OFP-100-S-W or OFP-100-S
OFP2-100-Q-NW Gold Support
GLD-OFP-100-Q
1 year of Gold Support for OFP2-100-Q, OFP2-100-Q-NW, OFP-100-Q-W or OFP-100-Q
GLD3-OFP-100-Q
3 years of Gold Support for OFP2-100-Q, OFP2-100-Q-NW, OFP-100-Q-W or OFP-100-Q
OFP-Q-ADD Gold Support
OptiFiber Pro Add on Kit - includes OptiFiber Pro Quad OTDR Module, (2) SC/LC Multimode Launch Cables—50 µm, (2) SC/LC Singlemode Launch Cable—9 µm, (2) OTDR source port interchangeable LC adapters, SC/SC Simplex Adaptor, LC/LC Simplex Adaptor, (2) Launch Fiber Hanging straps and magnets, Carry Case, Statement of Calibration and Getting Started Guide.See Photo
GLD-OFP-Q-ADD
1 year of Gold Support coverage for OFP-Q-ADD
GLD3-OFP-Q-ADD
3 years of Gold Support coverage for OFP-Q-ADD
OFP2-100-M Gold Support
OptiFiber Pro Multimode OTDR kit.
This kit includes (1) Versiv 2 Mainframe, (1) OptiFiber Pro Multimode OTDR module, Shoulder Strap, USB Interface Cable, Carry Case, AC Charger, Integrated Wi-Fi, Statement of Calibration and Getting Started Guides. See Photo
GLD-OFP-100-M
1 year of Gold Support for OFP2-100-M, OFP2-100-M-NW, OFP-100-M-W or OFP-100-M
GLD3-OFP-100-M
3 years of Gold Support for for OFP2-100-M, OFP2-100-M-NW, OFP-100-M-W or OFP-100-M
OFP2-100-MI Gold Support
OptiFiber Pro Multimode OTDR V2 kit with inspection kit with Wi-Fi. This kit includes (1) Versiv 2 Mainframe, (1) OptiFiber Pro Multimode OTDR module, Shoulder Strap, USB Interface Cable, Carry Case, AC Charger, (2) Quick Clean Cleaners (1.25/2.50 mm), (2) SC/LC Multimode Launch Cables—50 µm, (1) OTDR source port interchangeable LC adapters, USB Fiber Inspection Video Probe with 4 Tips, SC/SC Simplex Adaptor, (2) Launch Fiber Hanging straps and magnets, Integrated Wi-Fi, Statement of Calibration and Getting Started Guides. See Photo
GLD-OFP-100-MI
1 year of Gold Support for OFP2-100-MI, OFP-100-MI-W or OFP-100-MI
GLD3-OFP-100-MI
3 years of Gold Support for OFP2-100-MI, OFP-100-MI-W or OFP-100-MI
OFP2-100-S Gold Support
OptiFiber Pro Singlemode OTDR V2 kit with Wi-Fi. This kit includes (1) Versiv 2 Mainframe, (1) OptiFiber Pro Singlemode OTDR module, Shoulder Strap, USB Interface Cable, Carry Case, AC Charger, Integrated Wi-Fi, Statement of Calibration and Getting Started Guides. See Photo
GLD-OFP-100-S
1 year of Gold Support for OFP2-100-S, OFP2-100-S-NW, OFP-100-S-W or OFP-100-S
GLD3-OFP-100-S
3 years of Gold Support for OFP2-100-S, OFP2-100-S-NW, OFP-100-S-W or OFP-100-S
OFP2-100-SI Gold Support
OptiFiber Pro Singlemode OTDR V2 kit with inspection and Wi-Fi. This kit includes (1) Versiv 2 Mainframe, (1) OptiFiber Pro Singlemode OTDR module, Shoulder Strap, USB Interface Cable, Carry Case, AC Charger, (2) Quick Clean Cleaners (1.25/2.50 mm), (2) SC/LC Singlemode Launch Cables—9 µm, (1) OTDR source port interchangeable LC adapters, USB Fiber Inspection Video Probe with 4 Tips, SC/SC Simplex Adaptor, (2) Launch Fiber Hanging straps and magnets, Integrated Wi-Fi, Statement of Calibration and Getting Started Guides. See Photo
GLD-OFP-100-SI
1 year of Gold Support for OFP2-100-SI, OFP-100-SI-W or OFP-100-SI
GLD3-OFP-100-SI
3 year of Gold Support for OFP2-100-SI, OFP-100-SI-W or OFP-100-SI
OFP2-100-Q Gold Support
OptiFiber Pro Quad OTDR V2 kit with Wi-Fi. This kit includes (1) Versiv 2 Mainframe, (1) OptiFiber Pro Quad OTDR module, Shoulder Strap, Carry Case, USB Interface Cable, Carry Case, AC Charger, Integrated Wi-Fi, Statement of Calibration and Getting Started Guides. See Photo
GLD-OFP-100-Q
1 year of Gold Support for OFP2-100-Q, OFP2-100-Q-NW, OFP-100-Q-W or OFP-100-Q
GLD3-OFP-100-Q
3 years of Gold Support for OFP2-100-Q, OFP2-100-Q-NW, OFP-100-Q-W or OFP-100-Q
OFP2-100-Q with 1 year of Gold Support (available in the United States and Europe. Europe order: OFP2-100Q/GLD INT).
OFP2-100-QI Gold Support
OptiFiber Pro Quad OTDR V2 kit with inspection and Wi-Fi. This kit includes (1) Versiv 2 Mainframe, (1) OptiFiber Pro Quad OTDR module, Shoulder Strap, Carry Case, USB Interface Cable, AC Charger, (2) Quick Clean Cleaners (1.25/2.50 mm), (2) SC/LC Multimode Launch Cables—50 µm, (2) SC/LC Singlemode Launch Cables—9 µm, (2) OTDR source port interchangeable LC adapters, USB Fiber Inspection Video Probe with 4 Tips, SC/SC Simplex Adaptor, (2) Launch Fiber Hanging straps and magnets, Integrated Wi-Fi, Statement of Calibration and Getting Started Guides. See Photo
GLD-OFP-100-QI
1 year of Gold Support for OFP2-100-QI, OFP-100-QI-W or OFP-100-Q
GLD3-OFP-100-QI
3 years of Gold Support for OFP2-100-QI, OFP-100-QI-W or OFP-100-Q
OFP2-100-QI with 1 year of Gold Support (available in the United States and Europe. Europe order: OFP2-100QI/GLD INT).
OFP2-CFP-QI Gold Support
OptiFiber Pro Quad OTDR and CertiFiber Pro Quad V2 kit with inspection and Wi-Fi. This kit includes (1) Versiv 2 Mainframe & Remote, (1) OptiFiber Pro Quad OTDR module, (2) CertiFiber Pro Quad OLTS modules, (2) HandStraps, (2) Shoulder Straps, USB Interface Cable, Carry Case, (2) AC Chargers, (2) Quick Clean Cleaners (1.25/2.50 mm), (2) SC/LC Multimode Launch Cables—50 µm, (2) SC/LC Singlemode Launch Cables—9 µm, (2) OTDR source port interchangeable LC adapters, USB Fiber Inspection Video Probe with 4 Tips, SC/SC Simplex Adaptor, (2) LC/LC Simplex Adaptor, SC/LC SM TRC Kit 9 µm, SC/LC EFC TRC Kit 50 µm, Carry Case, (2) Launch Fiber Hanging straps and magnets, Integrated Wi-Fi, Statement of Calibration and Getting Started Guides. See Photo
GLD-OFP-CFP-QI
1 year of Gold Support coverage for OFP2-CFP-QI or OFP-CFP-QI
GLD3-OFP-CFP-QI
3 years of Gold Support coverage for OFP2-CFP-QI or OFP-CFP-QI
OptiFiber Pro HDR Singlemode OTDR V2 kit with Wi-Fi. This kit includes (1) Versiv 2 Mainframe, (1) OptiFiber Pro HDR Singlemode OTDR module (1310, 1550 nm), Shoulder Strap, USB Interface Cable, Carry Case, AC Charger, Integrated Wi-Fi, Statement of Calibration and Getting Started Guides. See Photo
OptiFiber Pro HDR Singlemode OTDR V2 kit with inspection and Wi-Fi This kit includes (1) Versiv 2 Mainframe, (1) OptiFiber Pro Singlemode HDR OTDR module (1310, 1550 nm), Shoulder Strap, USB Interface Cable, Carry Case, Versiv Field Case, AC Charger, 2.50 mm Quick Clean Cleaner, (2) SCAPC/SCAPC Singlemode Launch Cables—9 µm, USB Fiber Inspection Video Probe with 4 Tips, SCAPC/SCAPC Simplex Adaptor, (2) Launch Fiber Hanging straps and magnets, Integrated Wi-Fi, Statement of Calibration and Getting Started Guides. See Photo
OptiFiber Pro Singlemode + 1490 HDR OTDR V2 kit with Wi-Fi.
This kit includes (1) Versiv 2 Mainframe, (1) OptiFiber Pro HDR Singlemode +1490 OTDR module (1310, 1490, 1550 nm), Shoulder Strap, USB Interface Cable, Carry Case, AC Charger, Integrated Wi-Fi, Statement of Calibration and Getting Started Guides. See Photo
OptiFiber Pro Singlemode + 1490 HDR OTDR V2 kit with inspection and Wi-Fi.
This kit includes (1) Versiv 2 Mainframe, (1) OptiFiber Pro Singlemode + 1490 HDR OTDR module (1310, 1490, 1550 nm), Shoulder Strap, USB Interface Cable, Carry Case, Versiv Field Case, AC Charger, 2.50 mm Quick Clean Cleaner, (2) SCAPC/SCAPC Singlemode TRCs —9 µm, USB Fiber Inspection Video Probe with 4 Tips, SCAPC/SCAPC Simplex Adaptor, Integrated Wi-Fi, Statement of Calibration and Getting Started Guides. See Photo
OptiFiber Pro HDR OTDR V2 kit with Wi-Fi (1310, 1550, 1625 nm) OptiFiber Pro Singlemode + 1625 HDR OTDR V2 kit with Wi-Fi. This kit includes (1) Versiv 2 Mainframe, (1) OptiFiber Pro HDR Singlemode OTDR module (1310, 1550, 1625 nm), Shoulder Strap, USB Interface Cable, Carry Case, AC Charger, Integrated Wi-Fi, Statement of Calibration and Getting Started Guides. See Photo
OptiFiber Pro Singlemode + 1625 HDR OTDR V2 kit with Wi-Fi.
This kit includes (1) Versiv 2 Mainframe, (1) OptiFiber Pro Singlemode + 1625 HDR OTDR module (1310, 1550, 1625 nm), Shoulder Strap, USB Interface Cable, Carry Case, Versiv Field Case, AC Charger, 2.50 mm Quick Clean Cleaner, (2) SCAPC/SCAPC Singlemode TRCs-9 µm, USB Fiber Inspection Video Probe with 4 Tips, SCAPC/SCAPC Simplex Adaptor, Integrated Wi-Fi, Statement of Calibration and Getting Started Guides. See Photo
Accessories
Multimode 50µm launch cord (105m) for SC/SC See Photo
Multimode 50µm launch cord (105m) for SC/LC See Photo
1.25 mm APC universal video probe tip for patch cords. See Photo
MPO/APC probe tip and translator knob for patch cords and bulkheads. See Photo
Multimode 50µm launch cord (105m) for SC/E2K See Photo
Multimode 62.5µm launch cord (105m) for SC/LC See Photo
2.5 mm APC universal video probe tip for patch cord. See Photo
2.5 mm universal video probe tip for patch cords. See Photo
LC/APC bulkhead video probe tip. See Photo
E2000 bulkhead video probe tip. See Photo
Singlemode 9µm launch cord (160m) for SC/LC See Photo
SC/APC bulkhead video probe tip. See Photo
E2000/APC bulkhead video probe tip. See Photo
MU bulkhead video probe tip. See Photo
ST bulkhead video probe tip. See Photo
LC bulkhead video probe tip. See Photo
SC and FC bulkhead video probe tip. See Photo
Versiv Battery See Photo
Versiv Strap Kit See Photo
Singlemode 9µm launch cord (160m) for SC/SCAPC See Photo
Singlemode 9µm launch cord (160m) for SC/FCAPC See Photo
Singlemode 9µm launch cord (160m) for SC/LCAPC See Photo
Multimode 50µm launch cord (105m) for LC/LC See Photo
VERSIV Hardsided Case See Photo
Versiv Headphones See Photo
Enhanced Fiber Optic Cleaning Kit - Includes an Quick Clean 1.25mm cleaner, an Quick Clean 2.5mm cleaner, an Quick Clean MPO cleaner, a solvent pen, a cleaning cube and a softcase See Photo
Multimode 62.5µm launch cord (105m) for LC/LC See Photo
Singlemode 9µm launch cord (160m) for LC/LC See Photo
Single-mode reference grade 0.3 m for OTDR port (SC/SC)
Multimode 50µm TRC 0.3m for OTDR port (LC/LC)
Multimode 62.5µm TRC 0.3m for OTDR port (LC/LC)
Singlemode 9µm TRC 0.3M for OTDR port (LC/LC)
Multimode 50 µm (0.3 m) for OTDR port (SC/SC)
FI-1000 Gold Support
GLD-FI-1000
1 year Gold Support coverage for FI-1000
GLD3-FI-1000
3 years of Gold Support coverage for FI-1000
Versiv Small Carry Case. See Photo
Backpack strap for Versiv Large Case See Photo
Extended LC bulkhead video probe tip. See Photo
Video probe tip for LC simplex and duplex connectors. See Photo
MPO/APC probe tip and translator knob for multi-row patch cords and bulkheads. See Photo
WiFi Adapter for Versiv Mainframe. (Available in the following countries.)
30W Power Supply, 15V, 2A with US, EU, AU, and UK adapters See Photo
30W Power Supply, 15V, 2A with US, South Africa and India adapters See Photo
South Africa and India adapters for 30W power supply See Photo
Singlemode 9µm launch cord (160m) for SCAPC/LCUPC
Singlemode 9µm launch cord (160m) for SCAPC/LCAPC
Singlemode 9µm launch cord (160m) for SCAPC/E2KAPC
Singlemode 9µm launch cord (160m) for LCAPC/LCAPC
Singlemode 9µm launch cord (160m) for FCAPC/FCAPC
Singlemode 9µm launch cord (160m) for E2KAPC/E2KAPC
Singlemode 9µm TRC 0.3m for OTDR port (SCAPC/LCAPC)
Singlemode 9µm TRC (2m) for testing SCAPC/SCAPC
Singlemode 9µm TRC (2m) for testing SCAPC/LCAPC
VERSIV 2 MAIN REPLACEMENT
Versiv XL case. See Photo
Multimode 50 µm launch cord (105 m) for SC/ST See Photo
Specifications
Key OptiFiber Pro OTDR specifications
Multimode module
Singlemode module
Quad module
Wavelengths
850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
Compatible fiber types
50/125 µm
62.5/125 µm
Singlemode
50/125 µm
62.5/125 µm
Singlemode
Event dead zone 1
850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
Attenuation dead zone 2
850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
Dynamic range 3, 5, 6
850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
Max distance range setting
40 km
130 km
MM: 40 km
SM: 130 km
Distance measurement range 4, 5, 7, 8, 9, 10
850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
Reflectance range 4, 5
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65 dB (typical)
1550 nm: -14 dB to -65 dB (typical)
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65dB (typical)
1550 nm: -14 dB to -65 dB (typical)
Sample resolution
3 cm to 400 cm
3 cm to 400 cm
3 cm to 400 cm
Pulse widths (nominal)
850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns
850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns
Test time (per wavelength)
Auto setting: 5 sec (typical)
Quick test setting: 2 sec (typical)
Best resolution setting: 2 to 180 sec
FaultMap setting: 2 sec (typical), 180 sec (max)
DataCenter OTDR setting: 1 sec (typical at 850 nm), 7 sec (max)
Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Auto setting: 10 sec (typical)
Quick test setting: 5 sec (typical)
Best resolution setting: 5 to 180 sec
FaultMap setting: 10 sec (typical), 180 sec (max)
DataCenter OTDR setting: 20 sec (typical), 40 sec (max)
Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Auto setting:
MM – 5 sec (typical)
SM – 10 sec (typical)
Auto setting:
MM – 5 sec (typical)
SM – 10 sec (typical)
Quick test setting:
MM – 2 sec (typical)
SM – 5 sec (typical)
Best resolution setting:
MM – 2 to 180 sec M
SM – 5 to 180 sec
FaultMap setting:
MM - 2 sec (typical), MM - 180 sec (max)
SM - 10 sec (typical), SM - 180 sec (max)
DataCenter OTDR setting:
MM – 1 sec (typical at 850 nm) MM – 7 sec (max)
SM – 20 sec (typical) SM – 40 sec (max)
Manual setting:
-3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
1. Measured at 1.5 dB below non-saturating reflection peak with the shortest pulse width. Reflection peak < -40 dB for multimode and < - 50 dB for singlemode.
2. Measured at +/- 0.5 dB deviation from backscatter with the shortest pulse width. Reflection peak < -40 dB for multimode and < - 50 dB for singlemode.
3. For typical backscatter coefficient for OM1 fiber: 850: -65 dB, 1300: -72 dB.
4. Typical backscatter and attenuation coefficients for OM2-OM4 fiber: 850 nm: -68 dB; 2.3 dB/km: 1300 nm: -76 dB; 0.6 dB/km.
5. Typical backscatter and attenuation coefficients for OS1-OS2 fiber: 1310nm : -79 dB; 0.32 dB/km; 1550 nm: -82 dB; 0.19 dB/km.
6. SNR=1 method, 3 minute averaging, widest pulse width.
7. 850 = 9 km typical to find the end or 7 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
Key OptiFiber Pro HDR Specification
Wavelengths
1310 nm +/- 25 nm
1550 nm +/- 20 nm
1310 nm +/- 25 nm
1490 nm +/- 20 nm
1550 nm +/- 20 nm
1310 nm +/- 25 nm
1550 nm +/- 20 nm
1625 nm +/- 20 nm
Compatible fiber types
Singlemode
Singlemode
Singlemode
OTDR Port Connector
Cleanable APC ferrule with removable SC adapter
Cleanable APC ferrule with removable SC adapter
Cleanable APC ferrule with removable SC adapter
Event dead zone 1
0.7 m (typical)
0.7 m (typical)
0.7 m (typical)
Attenuation dead zone2
4m (typical)
4m (typical)
4m (typical)
PON dead zone3
30 m (typical)
30 m (typical)
30 m (typical)
Max distance range setting
260 km
260 km
260 km
Dynamic range 4, 5
1310 nm: 42 dB (typical
1550 nm: 41 dB (typical)
1310 nm: 42 dB (typical)
1490 nm: 41 dB (typical)
1550 nm: 41 dB (typical)
1310 nm: 42 dB (typical)
1550 nm: 41 dB (typical)
1625 nm: 40 dB (typical)
Reflectance range4
-14 to -70 dB (typical)
-14 to -70 dB (typical)
-14 to -70 dB (typical)
Sampling resolution
3 cm to 2 m
3 cm to 2 m
3 cm to 2 m
Sampling points
Up to 129000
Up to 129000
Up to 129000
Pulse widths (nominal)
5, 10, 30, 50, 100, 300, 500, 1000, 3000, 5000, 10000, 20000 ns
5, 10, 30, 50, 100, 300, 500, 1000, 3000, 5000, 10000, 20000 ns
5, 10, 30, 50, 100, 300, 500, 1000, 3000, 5000, 10000, 20000 ns
Distance uncertainty
+/-(1 + 0.0005*distance + 0.5*resolution)
+/-(1 + 0.0005*distance + 0.5*resolution)
+/-(1 + 0.0005*distance + 0.5*resolution)
Linearity
± 0.03 dB/dB
± 0.03 dB/dB
± 0.03 dB/dB
Reflectance uncertainty
±2 dB
±2 dB
±2 dB
Test Time (per wavelength)
Auto setting: 5 seconds/wavelength (typical)
Auto PON setting: 10 seconds/wavelength (typical)
Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength
Manual PON setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength
Quick test setting: 3 seconds/wavelength (typical)
Best resolution setting: 5 to 180 seconds/wavelength
Auto setting: 5 seconds/wavelength (typical)
Auto PON setting: 10 seconds/wavelength (typical)
Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength
Manual PON setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength
Quick test setting: 3 seconds/wavelength (typical)
Best resolution setting: 5 to 180 seconds/wavelength
Auto setting: 5 seconds/wavelength (typical)
Auto PON setting: 10 seconds/wavelength (typical)
Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength
Manual PON setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength
Quick test setting: 3 seconds/wavelength (typical)
Best resolution setting: 5 to 180 seconds/wavelength
Laser Classification
Class 1 CDRH Complies to EN 60825-2, 3rd Edition
Class 1 CDRH Complies to EN 60825-2, 3rd Edition
Class 1 CDRH Complies to EN 60825-2, 3rd Edition
Calibration Period
1 year
1 year
1 year
1. Measured at 1.5 dB below non-saturating reflection peak with the shortest pulse width. Reflection peak at - 50 dB.
2. Measured at +/- 0.5 dB deviation from backscatter with the shortest pulse width. Reflection peak‹ - 50 dB.
3. Measured at +/- 0.5 dB deviation from backscatter after 1:16 non-reflective splitter using 50 ns pulse width and 3 cm sampling resolution.
4. Typical backscatter coefficients for OS1-OS2 fiber: 1310 nm: -79 dB; 1490 nm: -81 dB; 1550 nm: -82 dB; 1625 nm: -84 dB.
5. 3 minute averaging, widest pulse width, 100 km fiber length, SNR = 1.
Additional key specifications
FiberInspector probe specification
Magnification
~ 200X with OptiFiber Pro Display
Light source
Blue LED
Power source
Versiv mainframe
Field of View (FOV)
Horizontal: 425 µm
Vertical: 320 µm
Minimum detectable particle size
0.5 µm
Dimensions
Approximately 6.75 in x 1.5 in (1175 mm x 35 mm) without adapter tip
Weight
200 g
Temperature range
Operating: 32°F to 122°F (0 °C to +50 °C)
Storage: -4°F to +158°F (-20°C to +70°C)
Certifications
CE (when used with the mainframe)
VFL specifications
On/Off control
Mechanical switch and a button on the touch screen
Output power
316 µW (-5 dBm) = peak power = 1.0 mW (0 dBm)
Operating wavelength
650 nm nominal
Spectral width (RMS)
±3 nm
Output modes
Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector adapter
2.5 mm universal
Laser safety (classification)
Class II CDRH Complies to EN 60825-2
General specifications
Weight
Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg)
Dimensions
Mainframe with module and battery: 2.625 in x 5.25 in x 11.0 in ( 6.67 cm x 13.33 cm x 27.94 cm)
Battery
Lithium ion battery pack, 7.2 volts
Battery life
Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Integrated Wi-Fi
Meets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz)
Charge Time
Tester Off
Four hours to charge from 10% to 90% capacity
Tester On
Six hours to charge from 10% to 90% capacity with the tester on
Environmental specifications
Operating temperature*
-10ºC to 45ºC
Storage Temperature
-10ºC to +60ºC
Operating altitude
4,000 m (13123 ft)
3200 m (10,500 ft) with ac adapter
Storage altitude
12,000 m
EMC
EN 61326-1
* Using battery power. With AC power: 0ºC to 45ºC. Real Time Trace function used for no more than 5 minutes in a 15-minute period. Maximum ambient temperature is 35ºC for continuous use of the Real Time Trace function.
* Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.