How To Do Bi-directional Tests for All IDs in a Set

In this procedure, you test all the links from End 1, then test them all again from End 2.

  1. On the home screen, tap the Next ID panel.
  2. If necessary, tap CHANGE CABLE IDs to select or make an ID set.
  3. On the CHANGE ID screen, turn on the Auto Save function and set the End 1/End 2 control to End 1.
  4. Enter names for the ends of the fiber (optional):
    1. On the CHANGE ID screen, tap the panel that shows End 1:.
    2. On the EDIT END NAME screen, tap the End 1 and End 2 panels to use the keyboard to enter names for each end. Tap DONE to save the names.
  5. Tap DONE on the CHANGE ID screen.
  6. Clean and inspect the connector for End 1 of the link that has the first ID in the set.
  7. Connect the tester to End 1 of the link, then tap TEST or press the TEST button.
  8. Clean and inspect the connector for End 1 of the link that has the next ID in the set.
  9. Connect the tester to End 1 of the next link, then tap TEST or press the TEST button.
  10. Repeat steps 8 and 9 for all IDs in the set.
  11. Press the HOME button, then tap the Next ID panel.
  12. On the CHANGE ID screen, tap the End 1/End 2 control at the top of the screen to make it show End 2. In the list under IDs Untested, the tester highlights the first ID that does not include results for End 2. This should be the first ID in the set.
  13. Tap DONE on the CHANGE ID screen.
  14. Clean and inspect the connector for End 2 of the link that has the first ID in the set.
  15. Connect the tester to End 2 of the link, then tap TEST or press the TEST button.
  16. Clean and inspect the connector for End 2 of the link that has the next ID in the set.
  17. Connect the tester to End 2 of the next link, then tap TEST or press the TEST button.
  18. Repeat steps 16 and 17 for all IDs in the set.

Related Products

                

                   

Versiv Kit Configurator

                   

How will you be using your Versiv