OptiFiber Pro is the first OTDR built from the ground up for enterprise fiber testing. OptiFiber Pro is focused on reducing costs while enhancing productivity and improving network reliability.
OptiFiber® Pro is the industry’s first OTDR built from the ground up to meet the challenges of enterprise fiber infrastructures. This troubleshooting and certification tool combines uncomplicated power, unparalleled efficiency and the exact functions needed for troubleshooting campus, data center and storage fiber networks.
The OptiFiber® Pro OTDR elevates fiber testing with the industry’s only smartphone interface that turns a technician into a fiber expert. The DataCenter OTDR configuration eliminates uncertainty and errors that occur when testing data center fiber. Its ultra-short dead zones enable testing of fiber patchcords in virtualized data centers. These capabilities, plus the fastest-in-the-industry trace times, make the OptiFiber Pro OTDR a must-have tool.
Most OTDRs are designed for a myriad of applications, causing the user interface to be difficult to navigate and interpret. OptiFiber Pro combines the latest “gesture-based” interface technology with a capacitive touchscreen to deliver the most innovative and user-friendly OTDR.
Advantages:

Driven by server virtualization and multi-gigabit links between servers, networks and storage, the datacenter architecture employs more patch cords and dense topology connectors, rendering carrier-class OTDRs with long dead zones ineffective. OptiFiber Pro not only makes fiber deployment in datacenters possible, but provides the highest level of accuracy for quick problem resolution.
With a simple one-touch selection, users enter DataCenter OTDR mode - without setup time for fine-tuning as needed in legacy OTDRs. DataCenter OTDR mode automatically detects OTDR parameters - end-detection algorithms, pulse widths, etc - without getting confused by the short links or number of connectors.
Advantages:

An important aspect in maximizing an OTDR’s value is to properly plan its day-to-day usage. With built-in project management, OptiFiber Pro allows a project manager to define each user’s role, settings and the associated tasks to be performed – transforming the OTDR into an all-in-one fiber testing tool complete with planning, inspection, certification and reporting.
OptiFiber Pro enhances job efficiency by allowing the workflow planner to create and manage operator and job profiles per project - defined jobs or sets of cable IDs can be assigned to specific operators. The progress and status of each project can also be easily monitored.
Advantages:

Extremely short event and attenuation dead zone
The OptiFiber Pro leverages the most sophisticated optical technology to provide the shortest event dead zone (0.5 m typical for MM) and attenuation dead zone (2.2 m typical for MM and 3.6 m typical for SM) of any OTDR. This technological advancement allows OptiFiber Pro to detect and measure closely spaced faults where no other OTDR can in today’s connector-rich datacenter and storage area environments.

LinkWare™ management software
Leveraging the popular and multi-featured LinkWare cable test management software application, OptiFiber Pro users can easily access the hassle-free project management, report generation, and software upgrade capabilities to manage workflow and consolidate test results.

Two second trace per wavelength
Another breakthrough with OptiFiber Pro is the data acquisition speed. While in Quick Test mode, a complete set of data is acquired in as little as two seconds per wavelength. OptiFiber Pro then analyzes the data and displays it as an EventMap, Table or Trace. The end result is less time spent testing and more time performing other tasks.

On-screen help – corrective action
On-screen “help” suggests corrective action(s) for resolving fiber problems during each testing step. The “help” offered is context sensitive which allows users to quickly pinpoint possible resolutions. An easy-to-read, gray icon in the bottom, left-hand corner shows detailed corrective action recommendations.

FiberInspector™ probe
OptiFiber Pro’s video inspection system examines patch cords and patch panel bulkheads to avoid the number one cause of fiber link failure – contamination. Significant time is saved because the probe is inserted directly into the patch panel’s bulkhead to examine installed fiber terminations without disassembling the patch panel. Technicians assign a pass or fail grade to the fiber, append a comment and save it for use in certification reports.

| Model Number/Name | Description |
| OFP-100-M | OptiFiber Pro Multimode OTDR kit. This kit includes the OptiFiber Pro with MM OTDR module, carrying strap, AC adapter/charger, USB interface cable – standard A to micro B, user guide CD, LinkWare software CD, Getting Started Guide, statement of calibration, registration card, factory-based warranty and carrying case. See Photo |
| OFP-100-M/GLD | OptiFiber Pro Multimode OTDR kit with 1 year of Gold Support coverage. |
| OFP-100-MI | OptiFiber Pro Multimode OTDR kit with inspection kit. This kit includes the OptiFiber Pro with MM OTDR module, 2 SC/LC multimode launch cables—50 µm, 1 SC/SC multimode launch cable—50 µm, USB fiber inspection video probe with 4 tips, 2 launch fiber tool packs, OptiFiber Pro carrying and hand strap, AC adapter/charger, USB interface cable – standard A to micro B, 1 1.25 mm IBC OneClick cleaner, 1 2.5 mm IBC OneClick cleaner, user guide CD, LinkWare software CD, Getting Started Guide, statement of calibration, registration card, factory-based warranty and carrying case. See Photo |
| OFP-100-MI/GLD | OptiFiber Pro Multimode OTDR with inspection kit and 1 year of Gold Support coverage. |
| OFP-100-S | OptiFiber Pro Singlemode OTDR kit. This kit includes the OptiFiber Pro with SM OTDR module, carrying strap, AC adapter/charger, USB interface cable – standard A to micro B, user guide CD, LinkWare software CD, Getting Started Guide, statement of calibration, registration card, factory-based warranty and carrying case. See Photo |
| OFP-100-S/GLD | OptiFiber Pro Singlemode OTDR kit with 1 year of Gold Support coverage. |
| OFP-100-SI | OptiFiber Pro Singlemode OTDR kit with inspection kit. This kit includes the OptiFiber Pro with SM OTDR module, 2 SC/LC multimode launch cables—9 µm, 1 SC/SC multimode launch cable—9 µm, USB fiber inspection video probe with 4 tips, 2 launch fiber tool packs, OptiFiber Pro carrying and hand strap, AC adapter/charger, USB interface cable – standard A to micro B, 1 1.25 mm IBC OneClick cleaner, 1 2.5 mm IBC OneClick cleaner, user guide CD, LinkWare software CD, Getting Started Guide, statement of calibration, registration card, factory-based warranty and carrying case. See Photo |
| OFP-100-SI/GLD | OptiFiber Pro Singlemode OTDR with inspection kit and 1 year of Gold Support coverage. |
| OFP-100-Q | OptiFiber Pro Quad OTDR kit. This kit includes the OptiFiber Pro with Quad OTDR module, carrying strap, AC adapter/charger, USB interface cable – standard A to micro B, user guide CD, LinkWare software CD, Getting Started Guide, statement of calibration, registration card, factory-based warranty and carrying case. See Photo |
| OFP-100-Q/GLD | OptiFiber Pro Quad OTDR kit with 1 year of Gold Support coverage. |
| OFP-100-QI | OptiFiber Pro Quad OTDR kit with inspection kit. This kit includes the OptiFiber Pro with Quad OTDR module, 2 SC/LC multimode launch cables—50 µm, 2 SC/LC singlemode launch cable—9 µm, 1 SC/SC multimode launch cables—50 µm, 1 SC/SC singlemode launch cable—9 µm, USB fiber inspection video probe with 4 tips, 2 launch fiber tool packs, OptiFiber Pro carrying and hand strap, AC adapter/charger, USB interface cable – standard A to micro B, 1 1.25 mm IBC OneClick cleaner, 1 2.5 mm IBC OneClick cleaner, user guide CD, LinkWare software CD, Getting Started Guide, statement of calibration, registration card, factory-based warranty and carrying case. See Photo |
| OFP-100-QI/GLD | OptiFiber Pro Quad OTDR with inspection kit and 1 year of Gold Support coverage. |
| OFP-MM | OptiFiber Pro Multimode OTDR module. See Photo |
| OFP-SM | OptiFiber Pro Singlemode OTDR kit. See Photo |
| OFP-QUAD | OptiFiber Pro Quad OTDR kit.See Photo |
| OFP-FI | DI-1000 Inspector with selective bulkhead and video probe tips. See Photo |
| TFS | TFS mainframe with battery. |
| Model Number/Name | Description |
| MMC-50-SCSC | Multimode launch cable 50 µm SC/SC |
| MMC-50-SCLC | Multimode launch cable 50 µm SC/LC |
| MMC-50-SCST | Multimode launch cable 50 µm SC/ST |
| MMC-50-SCFC | Multimode launch cable 50 µm SC/FC |
| MMC-50-SCE2K | Multimode launch cable 50 µm SC/E2K |
| MMC-62-SCSC | Multimode launch cable 62.5 µm SC/SC |
| MMC-62-SCLC | Multimode launch cable 62.5 µm SC/LC |
| MMC-62-SCST | Multimode launch cable 62.5 µm SC/ST |
| MMC-62-SCFC | Multimode launch cable 62.5 µm SC/FC |
| SMC-9-SCSC | Singlemode launch cable 9 µm SC/SC |
| SMC-9-SCLC | Singlemode launch cable 9 µm SC/LC |
| SMC-9-SCST | Singlemode launch cable 9 µm SC/ST |
| SMC-9-SCFC | Singlemode launch cable 9 µm SC/FC |
| SMC-9-SCE2KAPC | Singlemode launch cable 9 µm SC/E2000 APC |
| PA-SC | OTDR source port interchangeable SC adapter |
| PA-ST | OTDR source port interchangeable ST adapter |
| PA-FC | OTDR source port interchangeable FC adapter |
| TFS-BAT | TFS battery |
| TFS-CHGR | TFS AC adapter/charger, international |
| TFS-KIT-CASE | TFS soft case |
| TFS-HSTRAP | TFS hand strap |
| TFS-USB-CBL | USB interface cable standard A to micro B |
| FI1000 | FI-1000 FiberInspector USB video probe for OptiFiber Pro |
| FI1000-SCFC-TIP | SC and FC bulkhead video probe tip |
| FI1000-LC-TIP | LC bulkhead video probe tip |
| FI1000-ST-TIP | ST bulkhead video probe tip |
| FI1000-MU-TIP | MU bulkhead video probe tip |
| FI1000-E2KAPC-TIP | E2000/APC bulkhead video probe tip |
| FI1000-SCAPC-TIP | SC/APC bulkhead video probe tip |
| FI1000-E2K-TIP | E2000 bulkhead video probe tip |
| FI1000-LCAPC-TIP | LC/APC bulkhead video probe tip |
| FI1000-2.5-UTIP | 2.5 mm universal video probe tip for patch cords |
| FI1000-1.25-UTIP | 1.25 mm universal video probe tip for patch cords |
| FI1000-2.5APC-UTIP | 2.5 mm APC universal video probe tip for patch cord |
| FI1000-MPO-UTIP | MPO/MTP probe tip and translator knob for patch cords and bulkheads |
| FI1000-MPOAPC-UTIP | MPO/APC probe tip and translator knob for patch cords and bulkheads |
| FI1000-1.25APC-TIP | 1.25 mm APC universal video probe tip for patch cords |
| FI1000-MPOAPC-RT | MPO/MTP APC REPLACEMENT TIP WITH NO TRANSLATOR KNOB |
| FI1000-MPO-RT | MPO/MTP REPLACEMENT TIP WITH NO TRANSLATOR KNOB |
| FI1000-TIP-KIT | LC,FC/SC BULKHEAD, 1.25 AND 2.5MM UNIVERSAL TIPS IN A BOX |
| TFS-STD | TFS DEMO STAND |
| Model Number/Name | Description |
| GLD-OFP-100-Q | 1 year of Gold Support coverage for OptiFiber Pro OTDR - Model: OFP-100-Q (also available in 3-year coverage: GLD3-OFP-100-Q). |
| GLD-OFP-100-QI | 1 year of Gold Support coverage for OptiFiber Pro Quad OTDR kit - Model: OFP-100-QI (also available in 3-year coverage: GLD3-OFP-100-QI). |
| GLD-OFP-100-M/S | 1 year of Gold Support coverage for OptiFiber Pro Multimode or Singlemode OTDR kit - Models: OFP-100-M OR OFP-100-S (also available in 3-year coverage: GLD3-OFP-100-M/S). |
| GLD-OFP-100-MI/SI | 1 year of Gold Support coverage for OptiFiber Pro Multimode or Singlemode OTDR with inspection kit- Models: OFP-100-MI OR OFP-100-SI (also available in 3-year coverage: GLD3-OFP-100-MI/SI). |
| GLD-OFP-MOD-Q | 1 year of Gold Support coverage for OptiFiber Pro Quad OTDR kit - Model: OFP-QUAD |
| GLD-OFP-MOD-M/S | 1 year of Gold Support coverage for OptiFiber Pro Multimode or Singlemode module - Models: OFP-MM OR OFP-SM |
| GLD-FI | 1 year of Gold Support coverage for DI-1000 Inspector with selective bulkhead and video probe tips - - Model: OFP-FI |
| GLD-TFS | 1 year of Gold Support coverage for the TFS mainframe with battery - Model: TFS |
Key OTDR specifications
| Multimode module | Singlemode module | Quad module | |
| Wavelengths | 850 nm +/- 10 nm 1300 nm +35/-15 nm | 1310 nm +/- 25 nm 1550 nm +/- 30 nm | 850 nm +/- 10 nm 1300 nm +35/-15 nm 1310 nm +/- 25 nm 1550 nm +/- 30 nm |
| Compatible fiber types | 50/125 µm 62.5/125 µm | Singlemode | 50/125 µm 62.5/125 µm Singlemode |
| Event dead zone 1 | 850 nm: 0.5 m typical 1300 nm: 0.7 m typical | 1310 nm: 0.6 m typical 1550 nm: 0.6 m typical | 850 nm: 0.5 m typical 1300 nm: 0.7 m typical 1310 nm: 0.6 m typical 1550 nm: 0.6 m typical |
| Attenuation dead zone 2 | 850 nm: 2.2 m typical 1300 nm: 4.5 m typical | 1310 nm: 3.6 m typical 1550 nm: 3.7 m typical | 850 nm: 2.2 m typical 1300 nm: 4.5 m typical 1310 nm: 3.6 m typical 1550 nm: 3.7 m typical |
| Dynamic range 3, 5, 6 | 850 nm: 28 dB typical 1300 nm: 30 dB typical | 1310 nm: 32 dB typical 1550 nm: 30 dB typical | 850 nm: 28 dB typical 1300 nm: 30 dB typical 1310 nm: 32 dB typical 1550 nm: 30 dB typical |
| Max distance range setting | 40 km | 130 km | MM: 40 km SM: 130 km |
| Distance measurement range 4, 5, 7, 8, 9, 10 | 850 nm: 9 km 1300 nm: 35 km | 1310 nm: 80 km 1550 nm: 130 km | 850 nm: 9 km 1300 nm: 35 km 1310 nm: 80 km 1550 nm: 130 km |
| Reflectance range 4, 5 | 850 nm: -14 dB to -57 dB (typical) 1300 nm: -14 dB to -62 dB (typical) | 1310 nm: -14 dB to -65 dB (typical) 1550 nm: -14 dB to -65 dB (typical) | 850 nm: -14 dB to -57 dB (typical) 1300 nm: -14 dB to -62 dB (typical) 1310 nm: -14 dB to -65dB (typical) 1550 nm: -14 dB to -65 dB (typical) |
| Sample resolution | 3 cm to 400 cm | 3 cm to 400 cm | 3 cm to 400 cm |
| Pulse widths (nominal) | 850 nm: 3, 5, 20, 40, 200 ns 1300 nm: 3, 5, 20, 40, 200, 1000 ns | 1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns | 850 nm: 3, 5, 20, 40, 200 ns 1300 nm: 3, 5, 20, 40, 200, 1000 ns 1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns |
| Test time (per wavelength) | Auto setting: 5 sec (typical) | Auto setting: 10 sec (typical) | Auto setting: MM – 5 sec (typical) SM – 10 sec (typical) |
| Quick test setting: 2 sec (typical) | Quick test setting: 5 sec (typical) | Quick test setting: MM – 2 sec (typical) SM – 5 sec (typical) | |
| Best resolution setting: 2 to 180 sec | Best resolution setting: 5 to 180 sec | Best resolution setting: MM – 2 to 180 sec M SM – 5 to 180 sec | |
| FaultMap setting: 2 sec (typical), 180 sec (max) | FaultMap setting: 10 sec (typical), 180 sec (max) | FaultMap setting: MM - 2 sec (typical), MM - 180 sec (max) SM - 10 sec (typical), SM - 180 sec (max) | |
| DataCenter OTDR setting: 1 sec (typical at 850 nm), 7 sec (max) | DataCenter OTDR setting: 20 sec (typical), 40 sec (max) | DataCenter OTDR setting: MM – 1 sec (typical at 850 nm) MM – 7 sec (max) SM – 20 sec (typical) SM – 40 sec (max) | |
| Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 sec | Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 sec | Manual setting: -3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec |
Additional key specifications
| FiberInspector probe specification | |
| Magnification | ~ 200X with OptiFiber Pro Display |
| Light source | Blue LED |
| Power source | TFS mainframe |
| Field of View (FOV) | Horizontal: 425 µm Vertical: 320 µm |
| Minimum detectable particle size | 0.5 µm |
| Dimensions | Approximately 6.75 in x 1.5 in (1175 mm x 35 mm) without adapter tip |
| Weight | 200 g |
| Temperature range | Operating: 32°F to 122°F (0 °C to +50 °C) Storage: -4°F to +158°F (-20°C to +70°C) |
| Certifications | CE (when used with the mainframe) |
| VFL specifications | |
| On/Off control | Mechanical switch and a button on the touch screen |
| Output power | 316 µW (-5 dBm) = peak power = 1.0 mW (0 dBm) |
| Operating wavelength | 650 nm nominal |
| Spectral width (RMS) | ±3 nm |
| Output modes | Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency) |
| Connector adapter | 2.5 mm universal |
| Laser safety (classification) | Class II CDRH Complies to EN 60825-2 |
| General specifications | |
| Weight | Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg) |
| Dimensions | Mainframe with module and battery: 2.625 in x 5.25 in x 11.0 in ( 6.67 cm x 13.33 cm x 27.94 cm) |
| Battery | Lithium ion battery pack, 7.2 volts |
| Battery life | Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber |
| Charge Time | |
| Tester Off | Four hours to charge from 10% to 90% capacity |
| Tester On | Six hours to charge from 10% to 90% capacity with the tester on |
| Environmental specifications | |
| Operating temperature* | -18ºC to 45ºC |
| Non-operating temperature | -30ºC to 60ºC |
| Operating altitude | 4,000 m (13123 ft) 3200 m (10,500 ft) with ac adapter |
| Storage altitude | 12,000 m |
| EMC | EN 61326-1 |
* Using battery power. With AC power: 0ºC to 45ºC. Real Time Trace function used for no more than 5 minutes in a 15-minute period. Maximum ambient temperature is 35ºC for continuous use of the Real Time Trace function.
* Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.
| Title/Description | Download | |
Optical Fiber Test and Troubleshooting Solutions
A look at Fluke Networks' portfolio of fiber solutions. Discover which fiber test tools you need in your tool kit to best tackle any job. | Download PDF (2.35 MB) | |
iPad-ready Copper and Fiber Solutions Brochure
iPad-ready Copper and Fiber Solutions Brochure | Download PDF (19.86 MB) |
| Title/Description | Download | |
OptiFiber Pro OTDR Datasheet English
OptiFiber Pro OTDR Datasheet English | Download PDF (4.52 MB) |
| Title/Description | Download | |
Fluke Networks' Solution Catalog
64 page guide to selection and ordering Fluke Networks' Solutions and Products | Download PDF (6.39 MB) |
| Title/Description | Download | |
Choosing The Right OTDR White Paper
Choosing The Right OTDR White Paper | Download PDF (106 KB) |
| Title/Description | Download | |
Optifiber Pro Gold Benefits/value Flyer - US Priced
Optifiber Pro Gold Benefits/value Flyer - US Priced | Download PDF (443 KB) | |
Optifiber Pro OTDR Trade In Rebate Promo Form
Optifiber Pro OTDR Trade In Rebate Promo Form | Download PDF (456 KB) |
Gold Support for your OptiFiber Pro OTDR allows you to make the most of your purchase while ensuring a higher return on your investment. You will minimize your downtime, receive faster trouble resolution and have total access to all support resources.
What do you get with Gold Support for your OptiFiber Pro OTDR?
Repairs and loaner equipment - If your OptiFiber Pro OTDR should fail, we'll deliver a loaner unit via next-day delivery to keep you up and running. We'll repair your OptiFiber Pro OTDR and replace defective or faulty accessories at no charge, with first on bench" priority, and return it to you - all shipping paid by Fluke Networks.
Access to live 24 x 7 technical support - Extend the expertise of your staff. Gold Support includes direct, immediate telephone access to our world-class Technical Assistance Center (TAC), direct access only available to Gold Members. Our centers in Seattle, WA and Eindhoven, NL employ a full staff of highly trained technical experts that are on call, including weekends and through the night when most network changes are implemented, to answer complex troubleshooting questions helping you get the most out of your LinkRunner and understand the results you are seeing.
Accessory Replacement - Some accessories are essential to your OptiFiber Pro OTDR . The normal warranty on accessories is 90 days, but parts and accessories that shipped with your tester will be replaced free of charge with Gold Support once qualified as defective by our technical assistance center.
Software upgrades - Your OptiFiber Pro OTDR will never be out of date. You'll receive all software upgrades free.
Unlimited access to our Knowledge Base - You'll have an open door to valuable proprietary information we've gathered from helping customers over the years. It also includes helpful technical articles written by our experts.
Member Only promotions - Your membership qualifies you for Members Only promotions and programs. This includes product discounts, access to reconditioned equipment at special prices and other incredible values.
Ensure that you are getting the most out of your OptiFiber Pro OTDR with Gold Support Services. Buy Gold Support Today.