DTX CableAnalyzer™ Series

Copper certification tester guarantees cabling installations comply with all TIA/ISO standards. There is a newer model of this item: DSX-5000 CableAnalyzer™

  • Over 1 billion copper links certified to date
  • Independently verified by ETL to meet ISO Level IV and TIA Level IIIe Accuracy requirements
  • Analyze test results and create professional test reports using LinkWare reporting software
  • Endorsed by over 20 cable companies worldwide
  • Perform basic fiber certification with DTX modules
Next Generation
CableAnalyzer
Select Your Right
Tool
DTX Trade In Survey - Win
a $100 Gift Card
Talk to an Expert Where to Buy
 
 

Overview

The DTX CableAnalyzer Series from Fluke Networks is the testing platform for today and tomorrow. This revolutionary future-proof platform significantly reduces total time to certify by improving every aspect of the testing process. DTX CableAnalyzer Series significantly reduces your total time to certify. Time is money. DTX saves you both with

  • Cat 6 certification in 9 seconds
  • Advanced Diagnostics troubleshooting faults twice as fast
  • Fastest set up and results management times
  • Tester accuracy exceeding Levels IIIe and IV
  • UL Accuracy Classification

 

It starts with 9-second Cat 6 Autotest. That means you can meet TIA-568-C and ISO 11801:2002 certification requirements and receive structured cabling warranties faster than ever before. With all this speed also comes the highest accuracy as the DTX is the only tester to use a standards-compliant, electrically-centered permanent link test adapter. Furthermore, the DTX-1800 truly delivers on the promise of a future-proofing investment by measuring 10 Gig cable performance and Alien Crosstalk (ANEXT and AFEXT) in full compliance with the industry standards to 500 MHz. The AC Wiremap feature validates for Power over Ethernet services in accordance with TIA/EIA standards, even if a Midspan power supply is used. With over 50,000 units in use today, the DTX CableAnalyzer Series, is clearly the industry's choice as the most trusted cable certifier.

"We rely on Fluke Networks DTX-1800 to test and certify all the fiber and copper cabling at the Intel factory in Chandler, AZ. I have worked with other cable certifying machines, and hands down from speed to stability to the user interface, it is the best tool for the job."
Jeremy N.
IES Commercial
Mesa, AZ US

The DTX CableAnalyzer Series from Fluke Networks is the testing platform for today and tomorrow. This revolutionary future-proof platform significantly reduces total time to certify by improving every aspect of the testing process. DTX CableAnalyzer Series significantly reduces your total time to certify. Time is money. DTX saves you both with

  • Cat 6 certification in 9 seconds
  • Advanced Diagnostics troubleshooting faults twice as fast
  • Fastest set up and results management times
  • Tester accuracy exceeding Levels IIIe and IV
  • UL Accuracy Classification

 

It starts with 9-second Cat 6 Autotest. That means you can meet TIA-568-C and ISO 11801:2002 certification requirements and receive structured cabling warranties faster than ever before. With all this speed also comes the highest accuracy as the DTX is the only tester to use a standards-compliant, electrically-centered permanent link test adapter. Furthermore, the DTX-1800 truly delivers on the promise of a future-proofing investment by measuring 10 Gig cable performance and Alien Crosstalk (ANEXT and AFEXT) in full compliance with the industry standards to 500 MHz. The AC Wiremap feature validates for Power over Ethernet services in accordance with TIA/EIA standards, even if a Midspan power supply is used. With over 50,000 units in use today, the DTX CableAnalyzer Series, is clearly the industry's choice as the most trusted cable certifier.

 

Features

10 Gig Copper Certification

See how far the right tool can take you - from 10 Meg to 10 Gig

The DTX 10 Gig over Copper Test Solution enables cable testing and certification of twisted pair cabling for 10 Gigabit Ethernet deployments - whether it is an existing Cat 6 or newly installed Augmented Cat 6 cabling system.   The DTX 10 Gig over Copper Test Solution follows the DTX CableAnalyzer Series in our commitment to industry-leading performance, accuracy and ease-of-use.  

The DTX 10 Gig over Copper Test Solution Advantage

  • Simplifies complex Alien Crosstalk link-to-link certification by using the same user-friendly and intuitive DTX interface
  • The only solution to identify problematic cable(s) within the same bundle due to link-to-link crosstalk
  • The only solution that is fully compliant with industry standards
  • DTX 10 Gig Copper Kit together with DTX-1800 delivers on the promise of a future-proof investment - measuring  performance for 10 Gig and Alien Crosstalk (ANEXT and AFEXT) in full compliance with the industry standards to 500 MHz

The DTX 10 Gig Kit is now available.
 

DTX 10 Gig Kit
Copper Certification Kit
Alien Crosstalk Analyzer Kit for DTX-1800 includes: two DTX-AXTLK1 Communication Modules, Windows based DTX AxTalk Analyzer™ Software, two
Cat 6A/Class EA Permanent Link Adapters (DTX-PLA002S), two Channel Adapters optimized for Alien Crosstalk measurements to 500 MHz (DTX-CHA001AS), two Link Terminators (DTX-AXTERM) and two RJ45-to-RJ45 Couplers.

All items in this kit are packaged in a separate carrying case.

For an in-depth overview on the developments of the 10GBASE-T Standards including an overview on cabling types, best practices for design and installation and a technical look at Alien Crosstalk, download our whitepaper titled Testing Challenges for 10Gb/s Ethernet over Twisted-Pair Cabling (registration required).

Fiber Certification

Record-fast fiber certification – from 10 Meg to 10 Gig

 

DTX CableAnalyzer – a platform for growth

The only cable tester that can completely certify copper and fiber cabling.  Only the DTX platform offers optional on-board fiber modules for Basic (Tier 1) fiber certification and the DTX Compact OTDR module for Extended (Tier 2) certification. 

We engineered DTX Fiber Modules and DTX Compact OTDR to accelerate testing through exclusive technology and an easy-to-use interface. Our fiber modules let you test more fibers in less time minimizing costs and freeing you up for other tasks.  DTX Compact OTDR module speeds up Extended fiber certification and troubleshooting with unparalleled ease of use, wealth of installer-friendly features and the familiar user interface of the DTX CableAnalyzer.  Over time, the savings are substantial – hundreds of hours per year for the average contractor.

dtx cableanalyzer cable tester
 

Deliver complete fiber certification

Basic (Tier1) fiber certification.  DTX Fiber Modules provide a Basic (Tier 1) fiber certification solution – loss, length and polarity. Validate fiber link performance per industry standards. Measure optical loss at multiple wavelengths, measure fiber length and verify polarity. You can test two fibers in both directions at both wavelengths with incredible speed without swapping main and remote units, a capability only available from Fluke Networks. Interchangeable connector adapters allow reference and test connections that meet TIA/ISO standards for most SFF (small form factor) fiber connectors.

Unlike competitive fiber adapters which measure length and two loss measurements per Autotest, DTX is the only fiber test solution that measures length and four loss measurements per Autotest – all in about 12 seconds. With DTX Fiber Modules, you can speed through fiber testing five times faster than the competition.

Extended (Tier 2) fiber certification.  DTX Compact OTDR provides Extended (Tier 2) fiber certification.  It shoots and analyzes  traces on both multimode and singlemode fibers to check every connector and splice on a link making  sure that it meets defined specifications and installation quality expectations.

DTX Compact OTDR

DTX Compact OTDR - See how to transform your tester, your staff and your business

The DTX Compact OTDR is a full featured Optical Time Domain Reflectometer (OTDR) module that snaps onto the Fluke Networks DTX CableAnalyzer. It makes the DTX powerful certification tool a complete, easy-to-use OTDR that shoots and analyzes traces on singlemode and multimode fiber.  

DTX Compact OTDR side viewThe DTX Compact OTDR module makes every technician a fiber expert with unparalleled ease of use, automatic OTDR settings, loss limits for events and fiber links, launch fiber compensation, automatic event analysis, and results management - all with the familiar user interface of the DTX CableAnalyzer



One platform, many advantages


The DTX Compact OTDR Module leverages a contractor’s investment in the DTX CableAnalyzer by:technician using DTX Compact OTDR

  • Expanding installation revenue without expanding staff
  • Shortening the technicians’ learning curve for fiber testing
  • Performing Basic (Tier 1)* and Extended (Tier 2) fiber certification with a single tool
  • Accelerating troubleshooting with a powerful, single-ended OTDR
  • Delivering integrated copper and fiber reports using LinkWare™ Results Management Software

* Separate onboard fiber modules are required for Tier 1 Certification.


DTX Compact OTDR Specifications

DTX Compact OTDR Kits Options:

Patch Cord Test

Test the weakest link quickly, easily, and cost effectively with the DTX CableAnalyzer and Patch Cord Test Adapters.  The new adapters are the first of its kind to test shielded Category 5e, 6, and 6A cabling.  Simply snap a set of adapters onto your DTX CableAnalyzer and you can test shielded and unshielded twisted pair patch cords to industry performance standards.

Eliminate degradation of certified permanent links by ensuring the performance of patch cords before they are plugged in.  Reduce bit errors, increase channel margins, and minimize network downtime.

• Certify patch and equipment cords quickly (6-second Autotest for category 6)
• Test efficiently and accurately to Cat 5e, Cat 6, Cat 6A patch cord test requirements
• Ensure that patch cord performance meets the performance requirements of the installed links and industry standards
• Measure all key patch cord test parameters: wire map, length, propagation
delay, delay skew, NEXT, and Return Loss
• Trust the tester that industry experts use


Download datasheet to learn more about the new DTX CableAnalyzer Patch Cord Test Adapters

Coax Test Solution

Coax Test Solution

Test coax cable links quickly and easily with Coax Test Adapters
Extend the capabilities of your DTX CableAnalyzer to test coaxial cabling systems including legacy data cabling (such as 10BASE-2 or 10BASE-5 Ethernet) and video distribution coaxial cabling. Fluke Networks' new Coax Test Adapters and software upgrades add the following coaxial cabling tests to your DTX CableAnalyzer:

  • Length
  • Propagation delay
  • Cable (input) impedance
  • Insertion loss as a function of signal frequency


Cable Impedance
The cable input impedance characterizes the cable to be the proper type of coaxial cable such as 75 Ω cable versus a 50 Ω cable used in legacy Ethernet systems or 93 Ω cable. In addition, the tester performs a Time Domain Reflectometry (TDR) test of the link to ensure that the cable does not exhibit any significant changes in impedance. Such impedance anomalies can cause significant problems in the quality of the signal transmission.

Propagation Delay
Propagation delay measures the time required for signals to travel from one end of the cabling link to the other. The NVP of the cable, which indicates the speed of the electrical signals on the cable, is used to convert the propagation delay into the "electrical length" of the link. If the NVP is known with sufficient accuracy, the electrical length approximates the physical length closely.

Insertion Loss
With the DTX Coax Test Adapters, the DTX-1800 measures the insertion loss of the coaxial cable over the frequency range from 1 through 900 MHzx. The DTX-1200 measures insertion loss over the range from 1 - 350 MHz with the coax adapters. The tester stores the sweep diagrams that can be uploaded and stored on a PC using the LinkWare software.

Permanent Link Adapter Technology Eliminates False Failures

Commercial patch cords—including Cat 5e/6 and Cat 7 cords—used in Permanent Link testing applications can cause costly false failures by failing a good link and adding unnecessary hours of troubleshooting and repeat testing. The daily wear associated with coiling, uncoiling, and storing cables under rough field conditions causes slow, invisible degradation over time and contributes to Return Loss, which is often the cause of a FAIL.

At Fluke Networks, we put accuracy first. That's why we developed high-performance Permanent Link Adapters instead of using commercial patch cords. Our proprietary technology ensures superior accuracy and stability required for measuring Return Loss, while increasing the accuracy of all other measured test parameters—not just accuracy one time, but accuracy every time— over time.


As you can see in this graph, a commercial Cat 7 SSTP cord has a 10 dB loss after 150 cycles of coiling and uncoiling. This 10 dB degradation causes a good link to fail - and you end up with a false fail. This 10 dB of loss won't occur when you use Fluke Networks' Permanent Link adapter technology - with DTX you get repeatable accuracy you can count on.

PM06 Personality Modules

PM06 is the cabling industry's first centered, shielded test plug. With global industry approval by connectivity vendors, this unique "center plug" certifies link as well as connecting hardware compliance to the Cat 6 standard to achieve an "open" cabling system. Supports all UTP, FTP and ScTP cabling systems.

  • Centered TIA/ISO plug
  • Shielded - one global solution
  • Vendor independent
  • Snag-free clip
  • End-user assurance of interoperability
  • Designed for deep recessed jacks found in Europe

Testing 110-Style IDC Systems


Note:
Installations using IDC-type connectors not shown in this table may be tested against the test specification for the Permanent Link using the appropriate Basic Link Adapters. The basic link adapters available from Fluke Networks are listed on the DSP-4000 Series product page. Consult with the manufacturer of the connecting hardware to ensure that you certify the installation in agreement with his warranty requirements. To ensure reliable results for Return Loss, treat the twisted pair Basic Link Adapters cables with extra care.

Network Verification

Certify cabling, verify network availability and link connectivity

 

As network applications evolve and bandwidth demand increases, so do the testing requirements. Whether you are activating new service, upgrading new infrastructure, performing MACs, troubleshooting a cabling or link connectivity problems, new industry best practices now recommend verifying link connectivity and network availability after certifying each cabling link. They also recommend documenting results in one consolidated report. Doing so provides assurance to your customers that the network infrastructure was delivered in perfect working order. And the Fluke Networks DTX Series CableAnalyzer™ with the new DTX Network Service Module is the way to do just that.

Improve the services you offer
The same familiar tool used industry-wide to certify link transmission performance can now be used to verify and document the availability of network services over a cabling link. It is simple to operate and quickly provides powerful, valuable information. When you install new links and need to turn up the service the DTX tester with the Network Service Module lets you document all the network connectivity tests executed as an integrated part of the cable certification documentation provided by LinkWare. This allows you to provide clear evidence to your customers that the job was done right – according to standards and best practices. And, it lets you deliver improved services to end users, eliminate callbacks and reduce network downtime.


DTX Network Service Module:

  • Verify network service availability – determine whether a telecom outlet is active, identify its data rate (10/100/1000 connection), duplex capabilities, and whether power is available for PoE.
  • Check link utilization and error conditions – see Ethernet utilization of the link-under-test as a percentage of available bandwidth; identify broadcast traffic and the presence of networkerrors.
  • Port identification – blink switch/hub port light; verify if link-under-test is connected to the proper port or find out where a work area outlet is connected.
  • Verify link connectivity to the network up to 1 Gigabit Ethernet – use the DHCP server to getan IP address, ping the default router and DNS Server at 10, 100 or 1000 Mb/s. Or you can assign IP addresses manually to ping network devices.
  • Verify PoE – verify availability and voltage levels for links connected to power sourcing equipment to supply powered devices (PDs) for Power over Ethernet applications such as VoIP, network cameras, and wireless LAN Access Points.
  • Document both cabling link certification and network availability and link connectivity test results in one consolidated report using our LinkWare software.
  • Troubleshoot link – determine whether performance problems are cabling or network-related.
DTX AC Wiremap

AC Wiremap validates twisted-pair cabling for power over Ethernet services

Power over Ethernet (PoE) enables critical networks services including VoIP, web-based security and remote data capture. Midspan power supplies, an efficient means to implement PoE, have protection circuitry that makes it impossible to do wiremapping. The wiremap test is an essential tool for flushing out wiring errors that cause a PoE service to fail and troubleshooting existing PoE services.

The DTX CableAnalyzer now includes a feature called “DTX AC Wiremap” that overcomes these barriers. Cable installers can assure that cabling wired properly for PoE, testing it in accordance with TIA/EIA standards. Network technicians can test in accordance with TIA/EIA standards, rapidly detecting errors that may erupt in an ongoing service.

Fluke Networks pioneered new technology and test algorithms to address the issues unique to PoE, making them a standard feature software release 1.4 of the DTX product line.

dtx ac wiremap screenshot













 

 

 


A one-button test initiates DTX AC Wiremapping.


 DTX AC Wiremap Screenshot

The DTX user sees clearly if a connection is wired properly or has wiring errors. This test can be done from the location of the Ethernet switch(es), regardless of the presence or location of a Midspan power supply.

AC Wiremap test results can be integrated into LinkWare software, creating a comprehensive and professional report.

• Assures Ethernet cabling will support a service using Power over Ethernet, before turning it up
• Tests PoE cabling according to EIA/TIA standards, even when a Midspan supply is used
• Solves cabling problems in a PoE application quickly using one tool
• Lets you take full advantage of PoE services

 

LinkWare Reports

Save time managing results with LinkWare Cable Test Management Software

Fluke Networks' powerful LinkWare Software included with every DTX Series tester helps you quickly organize, edit, view, print, save, or archive test results by jobsite, customer, campus building, and more. You can merge test results into an existing database and then sort, search and organize by any number of data fields or parameters.

LinkWare is also available free from our web site. Once your work is done, you can give this powerful application to your customers so they can have instant access to the data electronically. You can also print test results or you can export the data as an Adobe Portable Document Format (PDF).

Extensive data management capabilities with LinkWare:

  • Manage copper and fiber test results with a single software application that supports Fluke Networks' entire line of cable testers
  • Deliver professional, customized, graphical reports in a common format for all Fluke Networks cable testers
  • Ensure standards compliance with the ability to configure and print TIA 606-A documentation
  • New drag and drop feature makes it easier to manage and organize multiple projects
  • Count on compatibility with major CMS (cable management software) applications
  • Increase productivity with simple user interface and time-saving features with LinkWare, the world's preferred cable test management software

LinkWare Software prints professional, graphical reports with color graphs depicting the measured test parameters. You can choose which parameters to print and the order in which graphs appear. Reports can also be customized with your company logo.

New LinkWare Stats option provides a graphical analysis of your entire cable plant
LinkWare now supports LinkWare Stats, a new automated statistical report option that allows you to move above and beyond the page-per-link report and see your entire cabling infrastructure. It analyzes and transforms LinkWare  test results data into charts and diagrams that reveal your cabling plant performance; this report summarizes your entire cabling infrastructure in a compact, graphical format that makes it easy to verify margins and to spot anomalies.

See what LinkWare Stats can do with your data - A free demo version of LinkWare Stats is included with every copy of LinkWare.

DTX Advantage

DTX CableAnalyzer Series significantly reduces your total time to certify.

Time is money. DTX saves you both.
The DTX CableAnalyzer Series delivers superior performance that can reduce your total certification costs by as much as 33% per year. This dramatic reduction is the result of not just faster testing, but also improved accuracy, superior diagnostics, longer battery life, simple user interface, and fast setup and reporting.

Cat 6 certification in 9 seconds
The DTX-1200 and DTX-1800 perform Cat 6 certification test in just 9 seconds - all in full compliance with the industry standards and with superior accuracy. That's three times faster than existing testers. This incredible speed means you can test up to 170 more links in an eight hour shift.

Advanced Diagnostics – troubleshoot faults twice as fast
When a link fails, the DTX Series provides quick and easy-to understand directions to identify the point of failure (distance from the tester) and the possible reason(s) for the failure. These directions not only tell you the problem, but also identify corrective actions your test technicians can take to solve the problem quickly -- all without having to consult with the project manager. Instead of spending time executing trial and error corrections and re-testing to find out whether the problem has been resolved -- the technician knows exactly where to look and what to do to fix the failing link.  

Fast even when you're not testing
The DTX Series isn't just a faster way to test. It's a faster way to do everything. It cuts setup and reporting times. Its ease-of-use lowers training times. Extended battery life means you can do more on a single charge. And a bright color display, ample memory, and built-in talk set all contribute to overall productivity while enhancing the user experience. This all adds up to save you time and money every day.

Tester accuracy exceeds Levels IIIe and IV
The DTX exceeds the  IEC Level IIIe specification with less than half the allowable crosstalk margin. A more demanding accuracy Level IV specification has been proposed in ISO/IEC (international standards) to test Class F links to 600 MHz. The DTX-1800 exceeds this specification, assuring you of higher confidence in results over the full frequency range.  The cost of inaccuracy:  A tester showing incorrect Pass/Fail results  may cause a good link to fail (false fail) or a bad link to pass (false pass). Both of these false results cost you time and money – with DTX you can rely on accurate results – every time.

UL Accuracy Classification
Fluke Networks' DTX Series was awarded the Underwriters Laboratories, Inc. (UL) Classification in accordance with the IEC- 61935-1 specifications for Accuracy Level IV and in accordance with the TIA-TSB-155 specifications for Accuracy Level IIIe. Accuracy Level IIIe will be required to test Cat 6 cabling for 10 Gigabit Ethernet deployments.

 

Models & Accessories

 
Models
Model Number/Name Description
DTX-1800

DTX-1800 CableAnalyzer: Includes DTX-1800 Main and Smart Remote, LinkWare PC Software, 128MB MMC Card, Cat 6A/Class EA Permanent Link Adapters (2), Cat 6A/Class EA Channel Adapters (2), Headsets for Talk (2), AC Chargers (2), Carrying Case, USB Interface Cable (Mini-B) & User Manual

DTX-1800 Gold Support:
GLD-DTX1 year of Gold Support coverage for the DTX CableAnalyzer and Smart Remote
GLD-DTX-3YEAR3 years of Gold Support coverage for the DTX CableAnalyzer and Smart Remote
DTX-1800 120/GLD

DTX-1800 CableAnalyzer with 1 Yr of Gold Support (available in the United States and Europe only. Europe order DTX-1800/GLD-EU)

DTX-1500

DTX-1500 CableAnalyzer: Includes DTX-1500 Main and Smart Remote, Cat 6A/Class EA Channel Adapters (2), Cat 6A Reference Patch Cord, Headsets for Talk (2), AC Chargers (2), Carrying Case, USB Interface Cable (Mini-B), User Manual. See Photo

DTX-1200

DTX-1200 CableAnalyzer: Includes DTX-1200 Main and Smart Remote, LinkWare PC Software, Cat 6A/Class EA Permanent Link Adapters (2), Cat 6A/Class EA Channel Adapters (2), Headsets for Talk (2), AC Chargers (2), Carrying Case, USB Interface Cable (Mini-B), User Manual

DTX-1200 Gold Support:
GLD-DTX1 year of Gold Support coverage for the DTX CableAnalyzer and Smart Remote
GLD-DTX-3YEAR3 years of Gold Support coverage for the DTX CableAnalyzer and Smart Remote
DTX-1200/GLD-EU

DTX-1200 CableAnalyzer with 1 Yr of Gold Support (available in Europe only). 

DTX-LT

DTX-LT CableAnalyzer: Includes DTX-LT Main and Smart Remote, LinkWare PC Software, Cat 6A/Class EA Permanent Link Adapters (2), 6A/Class EA Channel Adapter (1), AC Chargers (2), Carrying Case, USB Interface Cable (Mini-B), User Manual

DTX-LT Gold Support:
GLD-DTX1 year of Gold Support coverage for the DTX CableAnalyzer and Smart Remote
GLD-DTX-3YEAR3 years of Gold Support coverage for the DTX CableAnalyzer and Smart Remote
DTX-ELT
CableAnalyzer Category 6 Certifier for Electrical Installers (Only in EMEA's region)
DTX-ELT Gold Support:
GLD-DTX1 year of Gold Support coverage for the DTX CableAnalyzer and Smart Remote
GLD-DTX-3YEAR3 years of Gold Support coverage for the DTX CableAnalyzer and Smart Remote
DTX-ELTPRO
CableAnalyzer Category 6 Certifier for Electrical Installers with Permanent Link Adapters (Only in EMEA's region).
DTX-ELTPRO Gold Support:
GLD-DTX1 year of Gold Support coverage for the DTX CableAnalyzer and Smart Remote
GLD-DTX-3YEAR3 years of Gold Support coverage for the DTX CableAnalyzer and Smart Remote
 
Kits
Model Number/Name Description
DTX-1800-E

DTX-1800 and Set of two DTX Encircled Flux Multimode Fiber Modules, each incorporating:
850 nm and 1300 nm LED sources combined into a single output port
Set of Encircled Flux compliant test reference cords (EF-TRC)
850/1300/1310/1550 nm power meter
Integrated VFL

See Photo

DTX-1800-E Gold Support:
GLD-DTX-E1 year of Gold Support coverage for DTX-1800-E which includes Mainframe, Smart Remote and a set of DTX-EFM2 Multimode fiber modules.
GLD3-DTX-E3 yearS of Gold Support coverage for DTX-1800-E which includes Mainframe, Smart Remote and a set of DTX-EFM2 Multimode fiber modules.
DTX-1800-ES

DTX-1800 with Encircled Flux Multimode and Singlemode Fiber Modules: Includes DTX-1800 CableAnalyzer; 2 DTX-EFM2 Multimode Fiber Modules; 2 DTX-SFM2 Singlemode Fiber Modules; 2 Multimode Encircled Flux compliant test reference cords (EF-TRC); 2 Singlemode test reference cords (SM-TRC); 2 SC/SC Simplex Adapters; Carrying Case; and User Manuals

DTX-1800-ES Gold Support:
GLD-DTX-ES1 year of Gold Support coverage for DTX-1800-ES which includes Mainframe, Smart Remote, a set of DTX-EFM2 Multimode fiber modules and a set of DTX-SFM2 fiber modules.
GLD3-DTX-ES3 years of Gold Support coverage for DTX-1800-ES which includes Mainframe, Smart Remote, a set of DTX-EFM2 Multimode fiber modules and a set of DTX-SFM2 fiber modules.
DTX-1800-E 120/GLD

DTX-1800 with Encircled Flux Multimode Fiber Modules and 1 Yr of Gold Support (available in the United States and Europe only. Europe order DTX-1800-E/GLD-EU)

 
Accessories
Model Number/Name Description
DSP-PM11A
NORDX GIGABIX (T568A) Personality Module
DSP-PM11B
NORDX GIGABIX (T568B) Personality Module
LinkWare
LinkWare Cable Test Management Software: Free download at www.flukenetworks.com/linkware
LinkWare-Stats
LinkWare Stats: Statistical test results analysis software option for LinkWare
DTX-HCSE
HARD CARRYING CASE - DTX SERIES See Photo
DTX-TSET
Headset for DSP and DTX Cable Analyzers
DTX-ACUN
AC Charger Universal
DTX-ACNA
AC Charger, North America
DTX-CASE
Standard Carrying Case-DTX Series
DTX-STRP
DTX carrying strap
DTX-USB
USB Interface Cable (Mini-B)
DTX-SER
Serial RS-232 Cable (DB-9 to IEEE 1394)
DTX-LION
Lithium Ion Battery Pack
Copper Adapters and Accessories
DTX-10GKIT
Alien Crosstalk Analyzer Kit for DTX-1800 includes: two DTX-AXTLK1 Communication Modules, Windows based DTX AxTalk AnalyzerTM Software, two Cat 6A/Class EA Permanent Link Adapters (DTX-PLA002S), two Channel Adapters optimized for Alien Crosstalk measurement (DTX-CHA002S)
DTX-10GKIT Gold Support:
GLD-DTX-KIT1 year Gold Support coverage for DTX-10GKIT or DTX-AXKIT
GLD3-DTX-KIT3 years of Gold Support coverage for DTX-10GKIT or DTX-AXKIT
DTX-AXKIT
Alien Crosstalk Analyzer Kit for DTX-1800 includes: two DTX-AXTLK1 Communication Modules, Windows based DTX AxTalk AnalyzerTM Software, two Terminators (Common Mode and Differential Mode) and two 8-pin Couplers (CIQ-RJA).
DTX-AXKIT Gold Support:
GLD-DTX-KIT1 year Gold Support coverage for DTX-10GKIT or DTX-AXKIT
GLD3-DTX-KIT3 years of Gold Support coverage for DTX-10GKIT or DTX-AXKIT
DTX-NSM
The DTX Network Module plugs into the back of the main unit of the DTX tester. It performs network connectivity tests, tests Power over Ethernet according the standards and can analyze the network port the link is connected to.
DTX-COAX
DTX Coax Cable Test Adapter (2 adapters included)
DTX-PC5ES
DTX Patch Cord Test Adapter Set for Category 5e patch cords. Certifies both shielded and unshielded category 5e patch cords per ANSI/TIA 568-C and ISO 11801:2010.
DTX-PC6S
DTX Patch Cord Test Adapter Set for Category 6 patch cords. Certifies both shielded and unshielded category 6 patch cords per ANSI/TIA 568-C and ISO 11801:2010.
DTX-PC6AS

DTX Patch Cord Test Adapter Set for Category 6A patch cords. Certifies both shielded and unshielded category 6A patch cords per ISO 11801:2010.

DTX-PCTAC5EKS
Twin pack of shielded Cat 5e jacks. Recommended replacement for DTX-PC5ES Patch Cord Test adapters
DTX-PCTAC6KS
Twin pack of shielded Cat 6 jacks. Recommended replacement for DTX-PC6S Patch Cord Test adapters.
DTX-PCTAC6AKS

Twin pack of shielded Cat 6A jacks. Recommended replacement for DTX-PC6AS Patch Cord Test adapters.

DSP-PCI-C6JACK
Replacement Cat 6 Jacks for the DSP-PCI-C6 Patch Cord Adapter, set of 10
DTX-PLA002S
Set of 2 Permanent Link Adapters for Cat6A and Alien Crosstalk testing. This adapter can be used for all permanent link tests Cat6A/6/5e/5 and Cat 3.
DTX-PLA002
One Permanent Link Adapter for Cat 6A and Alien Cross Talk testing. This adapter can be used for all permanent link tests Cat 6A /6/5e/5 and Cat 3.
DTX-PLCAL
Permanent Link Adapter Field Calibration module. An automated procedure under 'Utilities' in LinkWare (v2.71 or later) allows the user to calibrate the Return Loss performance of the DTX-PLA002 adaptors using this module.
DTX-PLA002PRP
DTX-PLA002 plug replacement parts. This item includes two contact blocks of the 8-pin modular plug.
DTX-PLA001S
Set of 2 Permanent Link Adapters. This adapter is compatible with all DSP-PMxx Personality Modules.
DTX-PLA001
One Permanent Link Adapter for use with the DTX Series CableAnalyzer. This adapter is compatible with all DSP-PMxx Personality Modules but it does not include a Personality Module.
DTX-GG45-KIT
GG45 Adapter Kit
DTX-TERA
TERA Adapter Kit - Includes TERA Channel Adapters (2) and TERA Permanent Link Adapters (2) to test Siemon TERA class F systems
DTX-PLA011
One (1) TERA Permanent Link Adapter for Siemon TERA Class F and Fa Systems. Note: You will need at least one (1) DTX-CHA011 adapter as well.
DTX-CHA011
TERA Channel Adapter for Siemon TERA Class F Systems
DTX-CHA002S
Set of two Cat 6A/Class Ea Channel Adapters optimized for Alien Crosstalk measurements. These adapters can be used to test Cat 6A/ 6/ 5e/ 5/ 3 and Class Ea/E/D and C channels.
DTX-CHA002
Cat 6A/Class Ea Channel Adapter optimized for Alien Crosstalk measurements. This adapter can be used to test Cat 6A/6/ 5e/ 5/3 and Class Ea/E/D and C channels.
Fiber Modules and Accessories
MMC-50-SCSC

SC/SC LAUNCH FIBER 50 µm See Photo

MMC-50-SCLC
SC/LC LAUNCH FIBER 50 µm See Photo
MMC-50-LCLC
MULTIMODE LAUNCH CABLE 50µm LC/LC See Photo
MMC-50-SCST
SC/ST LAUNCH FIBER 50 µm See Photo
MMC-50-STST
MULTIMODE LAUNCH CABLE 50 µm ST/ST See Photo
MMC-50-SCFC
SC/FC LAUNCH FIBER 50 µm See Photo
MMC-50-FCFC
MULTIMODE LAUNCH CABLE 50µm FC/FC See Photo
MMC-50-SCE2K

SC/E2000 LAUNCH FIBER 50 µm See Photo

MMC-62-SCSC
SC/SC LAUNCH FIBER 62 µm See Photo
MMC-62-SCLC
SC/LC LAUNCH FIBER 62.5 µm See Photo
MMC-62.5-LCLC
MULTIMODE LAUNCH CABLE 62.5µm LC/LC See Photo
MMC-62-SCST
SC/ST LAUNCH FIBER 62.5 µm See Photo
MMC-62.5-STST
MULTIMODE LAUNCH CABLE 62.5µm ST/ST See Photo
MMC-62-SCFC
SC/FC LAUNCH FIBER 62.5 µm See Photo
MMC-62.5-FCFC
MULTIMODE LAUNCH CABLE 62.5µm FC/FC See Photo
SMC-9-SCSC
SC/SC LAUNCH FIBER SM See Photo
SMC-9-SCLC
SC/LC LAUNCH FIBER SM See Photo
SMC-9-LCLC
SINGLEMODE LAUNCH CABLE 9µm LC/LC See Photo
SMC-9-SCST
SC/ST LAUNCH FIBER SM See Photo
SMC-9-STST
SINGLEMODE LAUNCH CABLE 9 µm ST/ST See Photo
SMC-9-SCFC
SC/FC LAUNCH FIBER SM See Photo
SMC-9-FCFC
SINGLEMODE LAUNCH CABLE 9 µm FC/FC See Photo
SMC-9-SCE2KAPC
SC/E2000 LAUNCH FIBER SM See Photo
SMC-9-SCSCAPC
Singlemode launch cable 9 µm SC/SCAPC See Photo
SMC-9-SCFCAPC
Singlemode launch cable 9 µm SC/FCAPC See Photo
SMC-9-SCLCAPC
Singlemode launch cable 9 µm SC/LCAPC See Photo
DTX-SFM2
DTX Singlemode Fiber Modules - Includes two modules (one for Main and one for Smart Remote). each module contains 1310 nm and 1550 nm laser light source combined into single output port, 850-1550 nm power meter, integrated VFL, SC adapter for power meter and Singlemode SC-SC Test Reference Cords
DTX-SFM2 Gold Support:
GLD-DTX-FIBERMOD1 year of Gold Support coverage for one DTX fiber module set - Models: DTX-MFM2, DTX-GFM2 or DTX-SFM2.
GLD-DTXFMOD-3YEAR3 years of Gold Support coverage for one DTX fiber module set - Models: DTX-MFM2, DTX-GFM2 or DTX-SFM2.
DTX-EFM2

Set of two DTX Encircled Flux Multimode Fiber Modules, each incorporating:
850 nm and 1300 nm LED sources combined into a single output port
Set of Encircled Flux compliant test reference cords(EF-TRC)
850/1300/1310/1550 nm power meter
Integrated VFL

See Photo

DTX-EFM2 Gold Support:
GLD-DTX-EFM21 year of Gold Support coverage for one DTX Encircled Flux MM fiber module set - Model: DTX-EFM2
GLD3-DTX-EFM23 years of Gold Support coverage for one DTX Encircled Flux MM fiber module set - Model: DTX-EFM2
NFA-SC
Set of two SC Adapters for DTX-xFM2 power meter port.
NFA-LC
Set of two LC Adapters for DTX-xFM2 power meter port.
NFA-ST
Set of two ST Adapters for DTX-xFM2 power meter port.
NFA-FC
FC Test Adapters, Set of two
NFB1/2-LC/ST
A kit containing the Test Reference Cords sets NFK1-DPLX-LC, NFK1-DPLX-ST, NFK2-DPLX-LC, NFK2-DPLX-ST, LC and ST adapters for the power meter and 62.5/125 and 50/125
NFK1-DPLX-SC

Duplex MM 62.5µm TRC for SC Adapter

NFK1-DPLX-LC
Duplex MM 62.5µm TRC for LC Adapter
NFK1-DPLX-ST
Duplex MM 62.5µm TRC for ST Adapter
NFK1-DPLX-FC
Duplex MM 62.5µm TRC for FC Adapter
NFK2-DPLX-SC
Duplex MM 50µm TRC for SC Adapter
NFK2-DPLX-LC
Duplex MM 50µm TRC for LC Adapter
NFK2-DPLX-ST
Duplex MM 50µm TRC for ST Adapter
NFK2-DPLX-FC
Duplex MM 50µm TRC for FC Adapter
NFK3-DPLX-SC
Duplex SM 9µm TRC for SC Adapter
NFK3-DPLX-LC
Duplex SM 9µm TRC for LC Adapter
NFK3-DPLX-ST
Duplex SM 9µm TRC for ST Adapter
NFK3-DPLX-FC
Duplex SM 9µm TRC for FC Adapter
NFK1-LC
LC Accessory Kit, 62.5
NFK1-MANDREL-KIT
Multimode Fiber Mandrel kit containing two red mandrels for 50/125 µm cable and two gray mandrels for 62.5/125 µm cable
NF-MANDREL-50
Multimode Fiber Mandrel for 50/125
NF-MANDREL-625
Multimode Fiber Mandrel for 62.5/125
NFC-Kit-Case
Fiber Optic Cleaning Kit.
NF400
Fiber Accessories Carrying Case
DTX-FIBER-CASE
Protective carrying case for DTX Compact OTDR Kits
DTX-FBRCSE
Carry case for DTX-xFM or DTX-xFM2 Fiber Loss Test Modules with storage space for Test Reference Cords and fiber connector adapters
NFK1-EFLC-LC
One 62.5 µm SC/LC Encircled Flux Launch Controller (two required for DTX)
NFK2-EFLC-SC
One 50 µm SC/SC Encircled Flux Launch Controller (two required for DTX)
NFK1-EFLC-SC
One 62.5 µm SC/SC Encircled Flux Launch Controller (two required for DTX)
NFK2-EFLC-LC
One 50 µm SC/LC Encircled Flux Launch Controller (two required for DTX)
Personality Modules
DSP-PM19B
SYSTIMAX® VisiPatch® 360 (T568B) Personality Module
DSP-PM19A

SYSTIMAX® VisiPatch® 360 (T568A) Personality Module

DSP-PM17B
TYCO/AMP 610XC CONNECTOR (T568B) Personality Module
DSP-PM17A
TYCO/AMP 610XC CONNECTOR (T568A) Personality Module
DSP-PM16B
LEVITON 110 (T568B) Personality Module
DSP-PM16A
LEVITON 110 (T568A) Personality Module
DSP-PM15B
ADC/KRONE HIGHBAND (T568B) Personality Module
DSP-PM15A
ADC/KRONE HIGHBAND (T568A) Personality Module
DSP-PM14B
ADC/KRONE ULTIM8 (T568B) Personality Module
DSP-PM14A
ADC/KRONE ULTIM8 (T568A) Personality Module
DSP-PM13B
SIEMON S210 (T568B) Personality Module
DSP-PM13A
SIEMON S210 (T568A) Personality Module
DSP-PM12B
PANDUIT GIGAPUNCH (T568B) Personality Module
DSP-PM11B
Gerard Industries CP GigaPro (T568B) Personality Module
DSP-PM11A
Gerard Industries CP GigaPro (T568A) Personality Module
DSP-PM10B
SYSTIMAX® 110 (T568B) Personality Module
DSP-PM10A
SYSTIMAX® 110 (T568A) Personality Module
 

Specifications

 

 

Cable Types

Shielded and unshielded Twisted Pair (STP, FTP, SSTP and UTP) LAN cabling:

  • TIA Category 4, 5, 5e, 6 and 6A : 100 Ω
  • ISO/IEC Class C and D: 100 Ω and 120 Ω
  • ISO/IEC Class E, F and FA: 100 Ω

Standard Link Interface Adapters

Cat 6A/Class EA permanent link adapters:

  • TIA Cat 3, 4, 5, 5e, 6, 6A and ISO/IEC Class C, D, E and EA permanent link

Cat 6A/Class EA channel adapters:

  • TIA Cat 3, 4, 5, 5e, 6, 6A and ISO/IEC Class C, D, E and EA channels

Test Standards

  • TIA Category 3, 5e, 6 & 6A per ANSI/TIA-568-C.2
  • TIA Category 5 (1000BASE-T) per TIA TSB-95
  • TIA Category 6 per TIA/EIA-568B.2-1
  • TIA TSB-155 (DTX-1500, DTX-1800 only)
  • ISO TR 24750 (DTX-1500, DTX-1800 only)
  • ISO/IEC 11801 Class C, D, and E, EA & F
    • (EA: DTX-1500, DTX-1800 only)
    • (F: DTX-1800 only)
  • EN 50173 Class C, D, E, E& F
    • (EA: DTX-1500, DTX-1800 only)
    • (F: DTX-1800 only)
  • ANSI TP-PMD
  • IEEE 802.3 10BASE-T, 100BASE-TX, 1000BASE-T
    • (EA: DTX-1500, DTX-1800 only)
    • (F: DTX-1800 only)
  • IEEE 802.3an 10GBASE-T

Speed of Autotest

Full 2-way Autotest of Category 6 Twisted-Pair links in 9 seconds
Full 2-way Autotest of Category 6A and ISO/IEC Class F links in 22 seconds

Supported Tests Parameters

(The selected test standard determines the test parameters and the frequency range of the tests)

Wire Map
Length
Propagation Delay
Delay Skew
DC Loop Resistance
Insertion Loss (Attenuation)
Return Loss (RL), RL @ Remote
NEXT, NEXT @ Remote
Attenuation-to-crosstalk Ratio (ACR-N), ACR-N @ Remote
ACR-F (ELFEXT), ACR-F @ Remote
Power Sum ACR-F (ELFEXT), PS ACR-F @ Remote
Power Sum NEXT, PS NEXT @ Remote
Power Sum ACR-N, PS ACR-N @ Remote
Power Sum Alien Near End Xtalk (PS ANEXT)
Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)

Cable Tone Generator

Generates tones that can be detected by a tone probe such as a Fluke Networks IntelliTone probe. The tones are generated on all pairs. Frequency range on all pairs. Frequency range of tones: 440 Hz to 831 Hz

Display

3.7 in (9.4 cm) diagonal, 240 dots wide by 320 dots high, passive color, transmissive LCD with backlight.

Input Protection

Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage.

Case

High impact plastic with shock absorbing overmold

Dimensions

Main unit and Smart Remote: 8.5 in x 4.4 in x 2.4 in (21.6 cm x 11.2 cm x 6cm), nominal

Weight

2.4 lb (1.1 kg), nominal (without adapter or module)

Operating Temperature

32°F to 104°F (0°C to 40°C)

Storage Temperature

-4°F to 140°F (-20°C to 60°C)

Operating relative humidity (% RH without condensation)

32°F to 95 °F (0°C to 35°C): 0 % to 90 % 95°F to 113°F (35°C to 45°C): 0 % to 70 %

Vibration

Random, 2 g, 5 Hz -500 Hz

Shock

1 m drop test with and without module and adapter attached

Safety

CSA C22.2 No. 1010.1: 1992 EN 61010-1 1st Edition Amendments 1, 2

Pollution degree

Pollution Degree 2 as defined in IEC 60664 and applied to IEC 60950 "Safety of Information Technology Equipment, 1999"

Altitude

Operating: 4000 m (3048m with AC Adapter); Storage: 12000 m

EMC

EN 61326-1

Power

Main unit and remote: Lithium-ion battery pack, 7.4 V, 4000 mAh

  • Typical battery life: 12 to 14 hours
  • Charge time (with tester off): 4 hours (below 40 °C)
  • AC adapter/charger, USA version: Linear power supply; Input 108 V ac to 132 V ac, 60 Hz ; Output 15 V dc, 1.2 A
  • AC adapter/charger, international version: Switching power supply; Input 90 V ac to 264 V ac, 48 to 62 Hz; Output 15 V dc, 1.2 A (isolated output)
  • Memory backup power in main unit: Lithium battery
  • Typical life of lithium battery: 5 years
  • The battery will not charge at temperatures outside of 0°C to 45°C (32°F to 113°F). The battery charges at a reduced rate between 40°C and 45°C (104°F and 113°F).

Languages Supported

English, French, German, Spanish, Portuguese, Italian, Japanese, and Simplified Chinese, Traditional Chinese, Korean, Russian, Czech, Polish, Swedish, Hungarian.

Calibration

Service center calibration period is 1 year

Performance Specifications

Note: all specifications for tests on twisted-pair cabling apply to 100 Ω   cable. Contact Fluke Networks for information on measurement performance for cable with a different impedance.

Baseline accuracy

Exceeds the requirements of Level IV as in IEC 61935-1/Ed. 3

Category 6A/Class EA link test modes (and lower link categories)

DTX CableAnalyzer far exceeds Level III requirements of ANSI/TIA-1152 and IEC 61935-1/Ed.3

Class F link test modes

DTX-1800 meets or exceeds the requirements of Level IV as in IEC 61935-1/Ed. 3.

Length for Twisted Pair Cabling

(Length specs do not include the uncertainty of the cable's NVP Value)

Parameter

Single-ended Test
Dual-ended Test (Main and Remote)

Range

800 m (2600 ft) - Single-ended Test
150 m (490 ft) - Dual-ended Test (Main and Remote)

Resolution

0.1 m or 1 ft - Single-ended Test
0.1 m or 1 ft - Dual-ended Test (Main and Remote)

Accuracy

± (1m 4%) - Single-ended Test
± (1m 4%) - Dual-ended Test (Main and Remote)

Delay Skew

Parameter

Twisted Pair Cabling

Range

0 ns to 100 ns

Resolution

1 ns

Accuracy

± 10 ns

DC Loop Resistance Test

Parameter

Twisted Pair Cabling

Range

0 Ω  to 530 Ω

Resolution

0.1 Ω

Accuracy

± (1 Ω + 1 %)

Overload Recovery Time

Less than 10 minutes to rated accuracy following over-voltage. Referencing is required after repeated or prolonged over-voltage.

 

 

Documents

 

Brochures

Title/Description Download  
DTX Copper Cable Troubleshooting Handbook
Download PDF
4.39 MB
Fiber Troubleshooting Quick-Reference Guide
Test and Troubleshooting Guide for Optical Fiber Cabling and DataCommunications
Download PDF
2.59 MB
iPad-ready Copper and Fiber Solutions Brochure
Download PDF
8.7 MB
Optical Fiber Test and Troubleshooting Solutions
A look at Fluke Networks´ portfolio of fiber solutions. Discover which fiber test tools you need in your tool kit to best tackle any job.
Download PDF
2.2 MB
 

Data Sheets

Title/Description Download  
10 Gig Kit Data Sheet
Download PDF
1.89 MB
DTX CableAnalyzer Gold Benefits/value Flyer - US
DTX CableAnalyzer Gold Benefits/value Flyer
Download PDF
731.77 KB
DTX Fiber Extended Specifications Guide
Download PDF
439.07 KB
DTX Linkware Report
Download PDF
96.61 KB
DTX M12 Channel Adapters Datasheet
Download PDF
990.77 KB
DTX Network Service LinkWare Report
Download PDF
102.15 KB
DTX Network Service Module Data Sheet
Download PDF
528.96 KB
DTX Specification/Ordering Guide
Download PDF
122.16 KB
DTX-1500 Datasheet_EN
DTX-1500 Datasheet_EN
Download PDF
LinkWare Data Sheet
Download PDF
Patch Cord Test Adapter Data Sheet
Download PDF
362.94 KB
 

Catalogs

Title/Description Download  
Fluke Networks´ Solution Catalog NEW
68 page guide to selection and ordering Fluke Networks´ Solutions and Products
Download PDF
7.32 MB
 

Application Notes

Title/Description Download  
Certification Testing of Twisted Pair Patch Cords
Download PDF
787.35 KB
Copper Certification Testing Best Practices Pocket Guide
Download PDF
7.2 MB
DTX 10 Gig Diagnostics Application Note
Find out what you can do when cabling links fail compliance with the 10GBASE-T standard.
Download PDF
466.34 KB
Encircled Flux Application Note
How will Encircled Flux launch conditions improve my link loss measurements?
Download PDF
1.08 MB
Guide to Choosing the Right Cable Test Tool to Meet Your Testing Needs Application Note
Learn the distinction between the three cable test tool categories (verification, qualification and certification) so you can choose the tester that truly meets your testing needs.
Download PDF
374.29 KB
Hope is Not a Warranty Application Note
A warranty that is not based on proper certification testing documented by electronically retrievable test results only provides hope, not a solid assurance.
Download PDF
1.34 MB
How to get the most out of cable test reports Application Note
Learn how test results analysis software helps you to quickly see the true performance of the entire cabling plant and spot any anomalies or inconsistencies.
Download PDF
162.34 KB
How to Use the DTX-EFM2 Fiber Modules to Test Installed Corning Multimode Pretium EDGE Tap Modules
Application note
Download PDF
1.38 MB
How to Use the DTX-MFM2 Fiber Modules to Test Installed Corning Multimode Pretium EDGE Tap Modules
Application Note
Download PDF
1.21 MB
Verifying Network Service Availability Application Note
See how to verify and document the availability of network services over a cabling link with the DTX CableAnalzyer.
Download PDF
879.6 KB
 

White Papers

Title/Description Download  
Best Practices for Fiber Optic Installation Start with Inspection & Cleaning
This white paper will help you understand what to look for and when, how to inspect and clean and best practices for installation.
Download PDF
368.97 KB
Certifying Power Over Ethernet To Ensure Service Success
Download PDF
587.27 KB
Datacenter Virtualization White Paper
Connectivity in the Virtualized Datacenter: How to Ensure Next-Generation Services
Download PDF
1.83 MB
Ethernet In A Harsh Environment - White Paper
Whitepaper that discusses the unique issues that can arise when you deploy Ethernet in an industrial environment, and how to avoid production downtime caused by these issues.
Download PDF
60.48 KB
Fiber Test Best Practices: Tier 1 Certification
Download PDF
189.22 KB
Fiber Test Best Practices: Tier 2 Certification
Download PDF
136.71 KB
Finding your way in the maze of industrial Ethernet standards
Download PDF
436.36 KB
How to Certify or Re-certify Twisted-Pair Cabling for 10Gb/s Ethernet
Learn how new installation and testing guidelines help combat Alien Crosstalk.
Download PDF
1.1 MB
How to cable 802.11n Wireless Access Points
This paper discusses the impact 802.11n will have on cabling as well as what installers and enterprises should do to address them.
Download PDF
357.64 KB
Six Reasons Certification Is Essential White Paper
This paper identifies the specific benefits afforded by cable certification and how much it pays back to the network owner.
Download PDF
99.87 KB
Testing Power Over Ethernet (PoE) Enabled Systems Whitepaper
Understand the potential impacts on the certification and testing process.
Download PDF
226.16 KB
The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges White Paper
This paper revisits the Permanent Link test model, highlights its benefits, and examines its impact on the operations and performance requirements of field test equipment.
Download PDF
429.61 KB
White Paper: Benefits Of Industrial Standards In Industrial Ethernet Component Selection
The Role Standards Play in Selecting Industrial Ethernet Components
Download PDF
69.31 KB
White Paper: The High Cost of A Low-Cost Cable Certification Tester
The myriad of high hidden costs you may encounter when using a “low-cost” tester.
Download PDF
769.48 KB
Whitepaper: Troubleshooting Your Industrial Network
Download PDF
242.33 KB
 

Flyers

Title/Description Download  
CCTT DTX Series with 10Gig AXTalk Testing Course Outline
Download PDF
30.86 KB
Certified Cabling Test Technician (CCTT) DTX Course Overview Flyer
Download PDF
29.31 KB
Datacom CableAnalyzer Gold Membership Benefits - Overview
Versiv and DTX CableAnalyzer Gold Membership Benefits - Overview
Download PDF
1.46 MB
DTX 1500 Comparision Table
DTX 1500 Comparision Table
Download PDF
100.63 KB
DTX-1500 Flyer_EN
DTX-1500 Flyer_EN
Download PDF
1.5 MB
Fiber Test And Troubleshooting Instruments Comparison Guide
Download PDF
353.6 KB
Top 5 Reasons to Upgrade to Versiv
Download PDF
 

Gold Product Support

Gold Support for your DTX CableAnalyzer allows you to make the most of your DTX CableAnalyzer purchase while ensuring a higher return on your investment. You will minimize your downtime, receive faster trouble resolution and have total access to all support resources.

What do you get with Gold Support for your DTX CableAnalyzer and DTX Fiber modules?




Benefits

Standard Warranty

Gold Support

Live technical support and exclusive phone dial-in number 
FREE Annual Calibration and Factory Refresh 
FREE Repair with “first in bench” priority turnaround service 
 Loaner Equipment Service* 
FREE Accessory Replacements** 
Lifetime Buyback Guarantee 
 Member Only Promotions 
Access to Technical Support TeamWeb and EmailWeb, Email and Phone
Response Time from Technical Support<24 Hours<2 Hours
Customer Support – Phone and Email7am-5pm (Pacific Time)24x7x365
 Primary Case HandlingCustomer Service AgentTechnical Support Engineer
 Knowledge Base Access
 Product Documentation, White Paper downloads and Best Practice Guides
Online training Videos
Software and Firmware upgrades

*Available in certain geographies currently
**Applies to accessories in the original product purchase

Annual Calibration and Factory Refresh - ISO 9001 standards compliance requires annual unit calibration. Keeping your DTX CableAnalyzer and Fiber modules calibrated is critical to ensure accuracy when testing fiber networks. Our calibration processes are ISO-9001 controlled and designed to certify that your DTX and Fiber modules meet all published specifications. To receive a loaner unit during calibration (available in most regions), we recommend you schedule your appointment 6 weeks in advance of your required calibration date.  If a loaner is not required or calibration cannot be scheduled in advance, Gold customers may opt to instead receive a shipping waybill and calibrations will receive priority turnaround. Typical turnaround time for a calibration is 5 working days.  Your DTX unit and Fiber modules will be precisely calibrated to factory specifications (calibration certificate provide - calibration traceable with data available for extra charge), repaired as necessary with genuine OEM repair parts, upgraded with all of the latest software and firmware then cleaned and performance verified. In addition, all accessories that came with your DTX will be tested and replaced if faulty or defective.

Repairs and loaner equipment - If your DTX or Fiber Modules should fail, we'll deliver a loaner unit via next business day delivery to keep you up and running. We'll repair your DTX or Fiber modules and replace defective accessories that came with your unit at no charge, with "first on bench" priority, and return it to you - all shipping paid by Fluke Networks.

Accessory Replacement - Some accessories are essential to testing and certifying cable. If any accessory that comes with your DTX model are qualified as defective or faulty by our technical assistance center, it will be replaced free of charge. Universal Permanent Link Adapters and Modules are limited to replacement of one set per year, provided they have met the aforementioned criteria.

Covered accessories include:

Batteries Channel Adapter DSP-PM06 Personality Modules (1per year)
Chargers Cables Carrying cases Link Adapter (1 per year)

Gold Lifetime BuyBack Guarantee - Buy the tools you need now knowing that Fluke Networks will buy it back when it’s time for a new one.  Get 100% cash back within 30 days, 60% within 1 year, and 15% after a year for the life of your tester covered by Gold. (Full terms and conditions can be found at www.flukenetworks.com/GoldBuyBack.) (Currently not available within Asia)

Access to live 24 x 7 technical support - Extend the expertise of your staff. Gold Support includes priority access to our world-class Technical Assistance Center (TAC). Our centers in Seattle, WA and Eindhoven, NL employ a full staff of highly trained technical experts that are on call, including weekends and through the night, to answer complex troubleshooting questions, including GOLD only services such as: Test set-up and instrument configuration, Fiber testing and reference setting, Test results interpretation, including trace results analysis. Let us help you get the most out of your DTX and Fiber modules and understand the results you are seeing.

Member Only promotions - Your membership qualifies you for “Members Only” promotions and programs. This includes product discounts, access to reconditioned equipment at special prices and other incredible values.

Ensure that you are getting the most out of your DTX CableAnalyzer and Fiber Modules with Gold Support Services. Gold Support must be purchased for the Mainframe and Fiber Modules for complete coverage.

 

 

 

Endorsements

 

900 MHz and Class F (Cat 7) manufacturer’s endorsements
The top-of-the-line DTX CableAnalyzer — the DTX-1800 — supports testing up to 900 MHz. This extended bandwidth supports the ISO Class F links, as well as emerging standards like 10 Gigabit Ethernet over twisted-pair cabling. It also enables you to certify links for other applications, such as video distribution over twisted pair cabling. No other tester on the market gives you this kind of future-proof investment while meeting current Cat 5e/6 specifications.

Manufacturers are integral to the testing decisions you make. To support their warranties, your certification tests must be performed with approved tools so you can ensure your customers' complete satisfaction.

Fluke Networks has subjected the DTX Series testers to rigorous testing in the labs of leading wiring manufacturers. Click on the vendor logo below to display approval letter.
 

 ADC                                  AMP NETCONNECT                          Ackermann           
Addison  BKS  BTR IT Connect
Brand-Rex  CTI Netzwerksysteme     Corning
DatwylerFurukawaHCS
HellermanTytonHitachi CableHubbell
Infra+KerpenNCS
Nordx/CDTPanduitR&M
SetecSiemonSurtec
SYSTIMAXTKMTelegartner
TSUKOAT&T 


 

These Class F (Cat 7) certification endorsements complement the endorsements for certification of Cat 5e (Class D) and Cat 6 (Class E) links and channels.   Click on the vendor name to see approval letter.

 