The DTX CableAnalyzer Series from Fluke Networks is the testing platform for today and tomorrow. This revolutionary future-proof platform significantly reduces total time to certify by improving every aspect of the testing process. DTX CableAnalyzer Series significantly reduces your total time to certify. Time is money. DTX saves you both with
It starts with 9-second Cat 6 Autotest. That means you can meet TIA-568-C and ISO 11801:2002 certification requirements and receive structured cabling warranties faster than ever before. With all this speed also comes the highest accuracy as the DTX is the only tester to use a standards-compliant, electrically-centered permanent link test adapter. Furthermore, the DTX-1800 truly delivers on the promise of a futureproofing investment by measuring 10 Gig cable performance and Alien Crosstalk (ANEXT and AFEXT) in full compliance with the industry standards to 500 MHz. The AC Wiremap feature validates for Power over Ethernet services in accordance with TIA/EIA standards, even if a Midspan power supply is used. With over 50,000 units in use today, the DTX Series, is clearly the industry’s choice as the most trusted cable certifier.
See how far the right tool can take you - from 10 Meg to 10 Gig
The DTX 10 Gig over Copper Test Solution enables cable testing and certification of twisted pair cabling for 10 Gigabit Ethernet deployments - whether it is an existing Cat 6 or newly installed Augmented Cat 6 cabling system. The DTX 10 Gig over Copper Test Solution follows the DTX CableAnalyzer Series in our commitment to industry-leading performance, accuracy and ease-of-use.
The DTX 10 Gig over Copper Test Solution Advantage
The DTX 10 Gig Kit is now available.
DTX 10 Gig Kit
Alien Crosstalk Analyzer Kit for DTX-1800 includes: two DTX-AXTLK1 Communication Modules, Windows based DTX AxTalk Analyzer™ Software, two
Cat 6A/Class EA Permanent Link Adapters (DTX-PLA002S), two Channel Adapters optimized for Alien Crosstalk measurements to 500 MHz (DTX-CHA001AS), two Link Terminators (DTX-AXTERM) and two RJ45-to-RJ45 Couplers.
All items in this kit are packaged in a separate carrying case.
For an in-depth overview on the developments of the 10GBASE-T Standards including an overview on cabling types, best practices for design and installation and a technical look at Alien Crosstalk, download our whitepaper titled Testing Challenges for 10Gb/s Ethernet over Twisted-Pair Cabling (registration required).
Record-fast fiber certification – from 10 Meg to 10 Gig
DTX CableAnalyzer – a platform for growth
The only cable tester that can completely certify copper and fiber cabling. Only the DTX platform offers optional on-board fiber modules for Basic (Tier 1) fiber certification and the DTX Compact OTDR module for Extended (Tier 2) certification.
We engineered DTX Fiber Modules and DTX Compact OTDR to accelerate testing through exclusive technology and an easy-to-use interface. Our fiber modules let you test more fibers in less time minimizing costs and freeing you up for other tasks. DTX Compact OTDR module speeds up Extended fiber certification and troubleshooting with unparalleled ease of use, wealth of installer-friendly features and the familiar user interface of the DTX CableAnalyzer. Over time, the savings are substantial – hundreds of hours per year for the average contractor.
Deliver complete fiber certification
Basic (Tier1) fiber certification. DTX Fiber Modules provide a Basic (Tier 1) fiber certification solution – loss, length and polarity. Validate fiber link performance per industry standards. Measure optical loss at multiple wavelengths, measure fiber length and verify polarity. You can test two fibers in both directions at both wavelengths with incredible speed without swapping main and remote units, a capability only available from Fluke Networks. Interchangeable connector adapters allow reference and test connections that meet TIA/ISO standards for most SFF (small form factor) fiber connectors.
Unlike competitive fiber adapters which measure length and two loss measurements per Autotest, DTX is the only fiber test solution that measures length and four loss measurements per Autotest – all in about 12 seconds. With DTX Fiber Modules, you can speed through fiber testing five times faster than the competition.
Extended (Tier 2) fiber certification. DTX Compact OTDR provides Extended (Tier 2) fiber certification. It shoots and analyzes traces on both multimode and singlemode fibers to check every connector and splice on a link making sure that it meets defined specifications and installation quality expectations.
The DTX Compact OTDR is a full featured Optical Time Domain Reflectometer (OTDR) module that snaps onto the Fluke Networks DTX CableAnalyzer. It makes the DTX powerful certification tool a complete, easy-to-use OTDR that shoots and analyzes traces on singlemode and multimode fiber.
The DTX Compact OTDR module makes every technician a fiber expert with unparalleled ease of use, automatic OTDR settings, loss limits for events and fiber links, launch fiber compensation, automatic event analysis, and results management - all with the familiar user interface of the DTX CableAnalyzer
One platform, many advantages
The DTX Compact OTDR Module leverages a contractor’s investment in the DTX CableAnalyzer by:
* Separate onboard fiber modules are required for Tier 1 Certification.
DTX Compact OTDR Specifications
DTX Compact OTDR Kits Options:
Test the weakest link quickly, easily, and cost effectively with the DTX CableAnalyzer and Patch Cord Test Adapters. The new adapters are the first of its kind to test shielded Category 5e, 6, and 6A cabling. Simply snap a set of adapters onto your DTX CableAnalyzer and you can test shielded and unshielded twisted pair patch cords to industry performance standards.
Eliminate degradation of certified permanent links by ensuring the performance of patch cords before they are plugged in. Reduce bit errors, increase channel margins, and minimize network downtime.
• Certify patch and equipment cords quickly (6-second Autotest for category 6)
• Test efficiently and accurately to Cat 5e, Cat 6, Cat 6A patch cord test requirements
• Ensure that patch cord performance meets the performance requirements of the installed links and industry standards
• Measure all key patch cord test parameters: wire map, length, propagation
delay, delay skew, NEXT, and Return Loss
• Trust the tester that industry experts use
Download datasheet to learn more about the new DTX CableAnalyzer Patch Cord Test Adapters
Coax Test Solution
Test coax cable links quickly and easily with Coax Test Adapters
Extend the capabilities of your DTX CableAnalyzer to test coaxial cabling systems including legacy data cabling (such as 10BASE-2 or 10BASE-5 Ethernet) and video distribution coaxial cabling. Fluke Networks' new Coax Test Adapters and software upgrades add the following coaxial cabling tests to your DTX CableAnalyzer:
Cable Impedance
The cable input impedance characterizes the cable to be the proper type of coaxial cable such as 75 Ω cable versus a 50 Ω cable used in legacy Ethernet systems or 93 Ω cable. In addition, the tester performs a Time Domain Reflectometry (TDR) test of the link to ensure that the cable does not exhibit any significant changes in impedance. Such impedance anomalies can cause significant problems in the quality of the signal transmission.
Propagation Delay
Propagation delay measures the time required for signals to travel from one end of the cabling link to the other. The NVP of the cable, which indicates the speed of the electrical signals on the cable, is used to convert the propagation delay into the "electrical length" of the link. If the NVP is known with sufficient accuracy, the electrical length approximates the physical length closely.
Insertion Loss
With the DTX Coax Test Adapters, the DTX-1800 measures the insertion loss of the coaxial cable over the frequency range from 1 through 900 MHzx. The DTX-1200 measures insertion loss over the range from 1 - 350 MHz with the coax adapters. The tester stores the sweep diagrams that can be uploaded and stored on a PC using the LinkWare software.
Commercial patch cords—including Cat 5e/6 and Cat 7 cords—used in Permanent Link testing applications can cause costly false failures by failing a good link and adding unnecessary hours of troubleshooting and repeat testing. The daily wear associated with coiling, uncoiling, and storing cables under rough field conditions causes slow, invisible degradation over time and contributes to Return Loss, which is often the cause of a FAIL.
At Fluke Networks, we put accuracy first. That's why we developed high-performance Permanent Link Adapters instead of using commercial patch cords. Our proprietary technology ensures superior accuracy and stability required for measuring Return Loss, while increasing the accuracy of all other measured test parameters—not just accuracy one time, but accuracy every time— over time.

As you can see in this graph, a commercial Cat 7 SSTP cord has a 10 dB loss after 150 cycles of coiling and uncoiling. This 10 dB degradation causes a good link to fail - and you end up with a false fail. This 10 dB of loss won't occur when you use Fluke Networks' Permanent Link adapter technology - with DTX you get repeatable accuracy you can count on.
PM06 Personality Modules
PM06 is the cabling industry's first centered, shielded test plug. With global industry approval by connectivity vendors, this unique "center plug" certifies link as well as connecting hardware compliance to the Cat 6 standard to achieve an "open" cabling system. Supports all UTP, FTP and ScTP cabling systems.
Testing 110-Style IDC Systems
Note:
Installations using IDC-type connectors not shown in this table may be tested against the test specification for the Permanent Link using the appropriate Basic Link Adapters. The basic link adapters available from Fluke Networks are listed on the DSP-4000 Series product page. Consult with the manufacturer of the connecting hardware to ensure that you certify the installation in agreement with his warranty requirements. To ensure reliable results for Return Loss, treat the twisted pair Basic Link Adapters cables with extra care.
Certify cabling, verify network availability and link connectivity
As network applications evolve and bandwidth demand increases, so do the testing requirements. Whether you are activating new service, upgrading new infrastructure, performing MACs, troubleshooting a cabling or link connectivity problems, new industry best practices now recommend verifying link connectivity and network availability after certifying each cabling link. They also recommend documenting results in one consolidated report. Doing so provides assurance to your customers that the network infrastructure was delivered in perfect working order. And the Fluke Networks DTX Series CableAnalyzer™ with the new DTX Network Service Module is the way to do just that.
Improve the services you offer
The same familiar tool used industry-wide to certify link transmission performance can now be used to verify and document the availability of network services over a cabling link. It is simple to operate and quickly provides powerful, valuable information. When you install new links and need to turn up the service the DTX tester with the Network Service Module lets you document all the network connectivity tests executed as an integrated part of the cable certification documentation provided by LinkWare. This allows you to provide clear evidence to your customers that the job was done right – according to standards and best practices. And, it lets you deliver improved services to end users, eliminate callbacks and reduce network downtime.

DTX Network Service Module:
Power over Ethernet (PoE) enables critical networks services including VoIP, web-based security and remote data capture. Midspan power supplies, an efficient means to implement PoE, have protection circuitry that makes it impossible to do wiremapping. The wiremap test is an essential tool for flushing out wiring errors that cause a PoE service to fail and troubleshooting existing PoE services.
The DTX CableAnalyzer now includes a feature called “DTX AC Wiremap” that overcomes these barriers. Cable installers can assure that cabling wired properly for PoE, testing it in accordance with TIA/EIA standards. Network technicians can test in accordance with TIA/EIA standards, rapidly detecting errors that may erupt in an ongoing service.
Fluke Networks pioneered new technology and test algorithms to address the issues unique to PoE, making them a standard feature software release 1.4 of the DTX product line.
A one-button test initiates DTX AC Wiremapping.

The DTX user sees clearly if a connection is wired properly or has wiring errors. This test can be done from the location of the Ethernet switch(es), regardless of the presence or location of a Midspan power supply.
AC Wiremap test results can be integrated into LinkWare software, creating a comprehensive and professional report.
• Assures Ethernet cabling will support a service using Power over Ethernet, before turning it up
• Tests PoE cabling according to EIA/TIA standards, even when a Midspan supply is used
• Solves cabling problems in a PoE application quickly using one tool
• Lets you take full advantage of PoE services
Save time managing results with LinkWare Cable Test Management Software
Fluke Networks' powerful LinkWare Software included with every DTX Series tester helps you quickly organize, edit, view, print, save, or archive test results by jobsite, customer, campus building, and more. You can merge test results into an existing database and then sort, search and organize by any number of data fields or parameters.
LinkWare is also available free from our web site. Once your work is done, you can give this powerful application to your customers so they can have instant access to the data electronically. You can also print test results or you can export the data as an Adobe Portable Document Format (PDF).
Extensive data management capabilities with LinkWare:
LinkWare Software prints professional, graphical reports with color graphs depicting the measured test parameters. You can choose which parameters to print and the order in which graphs appear. Reports can also be customized with your company logo.
New LinkWare Stats option provides a graphical analysis of your entire cable plant
LinkWare now supports LinkWare Stats, a new automated statistical report option that allows you to move above and beyond the page-per-link report and see your entire cabling infrastructure. It analyzes and transforms LinkWare test results data into charts and diagrams that reveal your cabling plant performance; this report summarizes your entire cabling infrastructure in a compact, graphical format that makes it easy to verify margins and to spot anomalies.
See what LinkWare Stats can do with your data - A free demo version of LinkWare Stats is included with every copy of LinkWare.
DTX CableAnalyzer Series significantly reduces your total time to certify. Cat 6 certification in 9 seconds Advanced Diagnostics – troubleshoot faults twice as fast Fast even when you're not testing Tester accuracy exceeds Levels IIIe and IV UL Accuracy Classification
Time is money. DTX saves you both.
The DTX CableAnalyzer Series delivers superior performance that can reduce your total certification costs by as much as 33% per year. This dramatic reduction is the result of not just faster testing, but also improved accuracy, superior diagnostics, longer battery life, simple user interface, and fast setup and reporting.
The DTX-1200 and DTX-1800 perform Cat 6 certification test in just 9 seconds - all in full compliance with the industry standards and with superior accuracy. That's three times faster than existing testers. This incredible speed means you can test up to 170 more links in an eight hour shift.
When a link fails, the DTX Series provides quick and easy-to understand directions to identify the point of failure (distance from the tester) and the possible reason(s) for the failure. These directions not only tell you the problem, but also identify corrective actions your test technicians can take to solve the problem quickly -- all without having to consult with the project manager. Instead of spending time executing trial and error corrections and re-testing to find out whether the problem has been resolved -- the technician knows exactly where to look and what to do to fix the failing link.
The DTX Series isn't just a faster way to test. It's a faster way to do everything. It cuts setup and reporting times. Its ease-of-use lowers training times. Extended battery life means you can do more on a single charge. And a bright color display, ample memory, and built-in talk set all contribute to overall productivity while enhancing the user experience. This all adds up to save you time and money every day.
The DTX exceeds the IEC Level IIIe specification with less than half the allowable crosstalk margin. A more demanding accuracy Level IV specification has been proposed in ISO/IEC (international standards) to test Class F links to 600 MHz. The DTX-1800 exceeds this specification, assuring you of higher confidence in results over the full frequency range. The cost of inaccuracy: A tester showing incorrect Pass/Fail results may cause a good link to fail (false fail) or a bad link to pass (false pass). Both of these false results cost you time and money – with DTX you can rely on accurate results – every time.
Fluke Networks' DTX Series was awarded the Underwriters Laboratories, Inc. (UL) Classification in accordance with the IEC- 61935-1 specifications for Accuracy Level IV and in accordance with the TIA-TSB-155 specifications for Accuracy Level IIIe. Accuracy Level IIIe will be required to test Cat 6 cabling for 10 Gigabit Ethernet deployments.
| Model Number/Name | Description | ||||
| DTX-1800 | DTX-1800 CableAnalyzer: Includes DTX-1800 Main and Smart Remote, LinkWare PC Software, 128MB MMC Card, Cat 6A/Class EA Permanent Link Adapters (2), Cat 6A/Class E Channel Adapters (2), Headsets for Talk (2), AC Chargers (2), Carrying Case, USB Interface Cable (Mini-B) & User Manual | ||||
DTX-1800 Gold Support:
| |||||
| DTX-1800 120/GLD | DTX-1800 CableAnalyzer with 1 Yr of Gold Support (available in the United States and Europe only. Europe order DTX-1800/GLD-EU) | ||||
| DTX-1200 | DTX-1200 CableAnalyzer: Includes DTX-1200 Main and Smart Remote, LinkWare PC Software, Cat 6/Class E Permanent Link Adapters (2), Cat 6/Class E Channel Adapters (2), Headsets for Talk (2), AC Chargers (2), Carrying Case, USB Interface Cable (Mini-B), User Manual | ||||
DTX-1200 Gold Support:
| |||||
| DTX-1200/GLD-EU | DTX-1200 CableAnalyzer with 1 Yr of Gold Support (available in Europe only). | ||||
| DTX-LT | DTX-LT CableAnalyzer: Includes DTX-LT Main and Smart Remote, LinkWare PC Software, Cat 6/Class E Permanent Link Adapters (2), 6/Class E Channel Adapter (1), AC Chargers (2), Carrying Case, USB Interface Cable (Mini-B), User Manuals (2), Carrying Case, User Manual | ||||
DTX-LT Gold Support:
| |||||
| DTX-ELT | CableAnalyzer Category 6 Certifier for Electrical Installers (Only in EMEA's region) | ||||
DTX-ELT Gold Support:
| |||||
| DTX-CLT-J | CableAnalyzer Category 5e Certifier for Electrical Installers (Only in Japan’s region) | ||||
DTX-CLT-J Gold Support:
| |||||
| DTX-ELTPRO | CableAnalyzer Category 6 Certifier for Electrical Installers with Permanent Link Adapters (Only in EMEA's region). | ||||
DTX-ELTPRO Gold Support:
| |||||
| Model Number/Name | Description | ||||||||
| DTX-1800-MS | DTX-1800 with Multimode and Singlemode Fiber Modules: Includes DTX-1800 CableAnalyzer, set of DTX-MFM2 Multimode Fiber Modules and a set of DTX-SFM2 Singlemode Fiber Modules. See Photo | ||||||||
DTX-1800-MS Gold Support:
| |||||||||
| DTX-1800-MS120/GLD | DTX-1800 with Multimode and Singlemode Fiber Modules and 1 Yr of Gold Support (available in the United States and Europe only. Europe order DTX-1800-MS/GLD-EU) | ||||||||
| DTX-1800-M | DTX-1800 with Multimode Fiber Modules: Includes DTX-1800 CableAnalyzer and a set of DTX-MFM2 Multimode Fiber Modules. | ||||||||
DTX-1800-M Gold Support:
| |||||||||
| DTX-1800-M 120/GLD | DTX-1800 with Multimode Fiber Modules and 1 Yr of Gold Support (available in the United States and Europe only. Europe order DTX-1800-M/GLD-EU) | ||||||||
| DTX-1800-MO | A complete DTX-1800 CableAnalyzer, Multimode DTX MFM2 Fiber Modules, and a DTX Compact OTDR Module. See Photo | ||||||||
DTX-1800-MO Gold Support:
| |||||||||
| DTX-1800-MSO | DTX 1800 Copper/Fiber/OTDR Kit: Includes DTX-1800 CableAnalyzer, Sets of Multimode DTX MFM2 and Singlemode DTX SFM2 Fiber (loss/length) Modules, DTX Compact OTDR Module, launch fibers, accessories and carrying case(s). See Photo | ||||||||
DTX-1800-MSO Gold Support:
| |||||||||
| DTX-1800MSO120/GLD | DTX 1800 Copper/Fiber/OTDR Kit: Includes DTX-1800 CableAnalyzer, Sets of Multimode DTX MFM2, Singlemode DTX SFM2 Fiber (loss/length) Modules, DTX Compact OTDR Module and 1 Yr of Gold Support (available in the United States and Europe only. Europe order DTX-1800MSO/GLD-EU) | ||||||||
| DTX-QUAD-OTDR | DTX 1800 Compact OTDR Kit: Includes DTX-1800 CableAnalyzer mainframe and DTX Compact OTDR Module. See Photo | ||||||||
DTX-QUAD-OTDR Gold Support:
| |||||||||
| DTX-1200-M | DTX-1200 with Multimode Fiber Modules: Includes DTX-1200 CableAnalyzer with set of DTX-MFM2 Multimode Fiber Modules | ||||||||
DTX-1200-M Gold Support:
| |||||||||
| DTX-1800-0 | DTX-1800 CableAnalyzer with Compact OTDR for MM and SM Fiber testing | ||||||||
DTX-1800-0 Gold Support:
| |||||||||
| DTX-1200-MS | DTX-1200 with Multimode and Singlemode Fiber Modules: Includes DTX-1200 CableAnalyzer, set of DTX-MFM2 Multimode Fiber Modules and a set of DTX-SFM2 Singlemode Fiber Modules | ||||||||
DTX-1200-MS Gold Support:
| |||||||||
| DTX-1800-E | DTX-1800 and Set of two DTX Encircled Flux Multimode Fiber Modules, each incorporating: 850 nm and 1300 nm LED sources combined into a single output port Set of Encircled Flux compliant test reference cords (EF-TRC) 850/1300/1310/1550 nm power meter Integrated VFL See Photo | ||||||||
DTX-1800-E Gold Support:
| |||||||||
| Model Number/Name | Description | ||||
| DTX-OTDR-QMOD | DTX Compact OTDR Module: Includes 850/1300/1310/1550 OTDR Module and carrying case | ||||
DTX-OTDR-QMOD Gold Support:
| |||||
| DTX-1800/SR | DTX-1800 Smart Remote Add-on | ||||
| DTX-LT/SR | DTX-LT Smart Remote Add-on | ||||
| Model Number/Name | Description | ||||
| DSP-PM11A | NORDX GIGABIX (T568A) Personality Module | ||||
| DSP-PM11B | NORDX GIGABIX (T568B) Personality Module | ||||
| LinkWare | LinkWare Cable Test Management Software: Free download at www.flukenetworks.com/linkware | ||||
| LinkWare-Stats | LinkWare Stats: Statistical test results analysis software option for LinkWare | ||||
| NFK1-EFLC-SC | One 62.5 µm SC/SC Encircled Flux Launch Controller (two required for DTX) | ||||
| NFK1-EFLC-LC | One 62.5 µm SC/LC Encircled Flux Launch Controller (two required for DTX) | ||||
| NFK2-EFLC-SC | One 50 µm SC/SC Encircled Flux Launch Controller (two required for DTX) | ||||
| NFK2-EFLC-LC | One 50 µm SC/LC Encircled Flux Launch Controller (two required for DTX) | ||||
| DTX-HCSE | HARD CARRYING CASE - DTX SERIES See Photo | ||||
| DTX-TSET | Headset for DSP and DTX Cable Analyzers | ||||
| DTX-ACUN | AC Charger Universal | ||||
| DTX-ACNA | AC Charger, North America | ||||
| DTX-CASE | Standard Carrying Case-DTX Series | ||||
| DTX-STRP | DTX carrying strap | ||||
| DTX-USB | USB Interface Cable (Mini-B) | ||||
| DTX-SER | Serial RS-232 Cable (DB-9 to IEEE 1394) | ||||
| DTX-LION | Lithium Ion Battery Pack | ||||
| Copper Adapters and Accessories | |||||
| DTX-10GKIT | Alien Crosstalk Analyzer Kit for DTX-1800 includes: two DTX-AXTLK1 Communication Modules, Windows based DTX AxTalk AnalyzerTM Software, two Cat 6A/Class EA Permanent Link Adapters (DTX-PLA002S), two Channel Adapters optimized for Alien Crosstalk measurement (DTX-CHA002AS) | ||||
DTX-10GKIT Gold Support:
| |||||
| DTX-AXKIT | Alien Crosstalk Analyzer Kit for DTX-1800 includes: two DTX-AXTLK1 Communication Modules, Windows based DTX AxTalk AnalyzerTM Software, two Terminators (Common Mode and Differential Mode) and two 8-pin Couplers (CIQ-RJA). | ||||
DTX-AXKIT Gold Support:
| |||||
| DTX-NSM | The DTX Network Module plugs into the back of the main unit of the DTX tester. It performs network connectivity tests, tests Power over Ethernet according the standards and can analyze the network port the link is connected to. | ||||
| DTX-COAX | DTX Coax Cable Test Adapter (2 adapters included) | ||||
| DTX-PC5ES | DTX Patch Cord Test Adapter Set for Category 5e patch cords. Certifies both shielded and unshielded category 5e patch cords per ANSI/TIA 568-C and ISO 11801:2010. See Photo | ||||
| DTX-PC6S | DTX Patch Cord Test Adapter Set for Category 6 patch cords. Certifies both shielded and unshielded category 6 patch cords per ANSI/TIA 568-C and ISO 11801:2010. See Photo | ||||
| DTX-PC6AS | DTX Patch Cord Test Adapter Set for Category 6A patch cords. Certifies both shielded and unshielded category 6A patch cords per ISO 11801:2010. | ||||
| DTX-PCTAC5EKS | Twin pack of shielded Cat 5e jacks. Recommended replacement for DTX-PC5ES Patch Cord Test adapters | ||||
| DTX-PCTAC6KS | Twin pack of shielded Cat 6 jacks. Recommended replacement for DTX-PC6S Patch Cord Test adapters. | ||||
| DTX-PCTAC6AKS | Twin pack of shielded Cat 6A jacks. Recommended replacement for DTX-PC6AS Patch Cord Test adapters. | ||||
| DSP-PCI-C6JACK | Replacement Cat 6 Jacks for the DSP-PCI-C6 Patch Cord Adapter, set of 10 | ||||
| DTX-PLA002S | Set of 2 Permanent Link Adapters for Cat6A and Alien Crosstalk testing. This adapter can be used for all permanent link tests Cat6A/6/5e/5 and Cat 3. | ||||
| DTX-PLA002 | One Permanent Link Adapter for Cat 6A and Alien Cross Talk testing. This adapter can be used for all permanent link tests Cat 6A /6/5e/5 and Cat 3. | ||||
| DTX-PLCAL | Permanent Link Adapter Field Calibration module. An automated procedure under 'Utilities' in LinkWare (v2.71 or later) allows the user to calibrate the Return Loss performance of the DTX-PLA002 adaptors using this module. | ||||
| DTX-PLA002PRP | DTX-PLA002 plug replacement parts. This item includes two contact blocks of the 8-pin modular plug. | ||||
| DTX-PLA001S | Set of 2 Permanent Link Adapters with PM06 Personality Modules. This adapter is compatible with all DSP-PMxx Personality Modules. | ||||
| DTX-PLA001 | One Permanent Link Adapter for use with the DTX Series CableAnalyzer. This adapter is compatible with all DSP-PMxx Personality Modules but it does not include a Personality Module. | ||||
| DTX-GG45-KIT | GG45 Adapter Kit | ||||
| DTX-TERA | TERA Adapter Kit - Includes TERA Channel Adapters (2) and TERA Permanent Link Adapters (2) to test Siemon TERA class F systems | ||||
| DTX-PLA011 | One (1) TERA Permanent Link Adapter for Siemon TERA Class F and Fa Systems. Note: You will need at least one (1) DTX-CHA011 adapter as well. | ||||
| DTX-CHA011 | TERA Channel Adapter for Siemon TERA Class F Systems | ||||
| DTX-CHA002S | Set of two Cat 6A/Class Ea Channel Adapters optimized for Alien Crosstalk measurements. These adapters can be used to test Cat 6A/ 6/ 5e/ 5/ 3 and Class Ea/E/D and C channels. | ||||
| DTX-CHA002 | Cat 6A/Class Ea Channel Adapter optimized for Alien Crosstalk measurements. This adapter can be used to test Cat 6A/6/ 5e/ 5/3 and Class Ea/E/D and C channels. | ||||
| Fiber Modules and Accessories | |||||
| SMC-9-SCE2KAPC | SC/E2000 LAUNCH FIBER SM | ||||
| SMC-9-SCFC | SC/FC LAUNCH FIBER SM | ||||
| SMC-9-SCLC | SC/LC LAUNCH FIBER SM | ||||
| SMC-9-SCST | SC/ST LAUNCH FIBER SM | ||||
| SMC-9-SCSC | SC/SC LAUNCH FIBER SM | ||||
| MMC-50-SCE2K | SC/E2000 LAUNCH FIBER 50 µm | ||||
| MMC-50-SCFC | SC/FC LAUNCH FIBER 50 µm | ||||
| MMC-50-SCLC | SC/LC LAUNCH FIBER 50 µm | ||||
| MMC-50-SCST | SC/ST LAUNCH FIBER 50 µm | ||||
| MMC-50-SCSC | SC/SC LAUNCH FIBER 50 µm | ||||
| MMC-62-SCFC | SC/FC LAUNCH FIBER 62.5 µm | ||||
| MMC-62-SCLC | SC/LC LAUNCH FIBER 62.5 µm | ||||
| MMC-62-SCST | SC/ST LAUNCH FIBER 62.5 µm | ||||
| MMC-62-SCSC | SC/SC LAUNCH FIBER 62 µm | ||||
| DTX-MFM2 | DTX Multimode Fiber Modules - Includes two modules (one for Main and one for Smart Remote). Each module contains 850nm and 1300nm LED light source combined into single output port, 850-1550 nm optical power meter, integrated VFL, SC adapter for power meter and a set of 62.5/125 SC-SC and 50/125 SC-SC Test Reference Cords with Mandrels (NF-MANDREL-50 and NF-MANDREL-625) | ||||
DTX-MFM2 Gold Support:
| |||||
| DTX-GFM2 | DTX Gigabit Multimode Fiber Modules - Includes two modules each incorporating: 850nm VCSEL source and 1310nm laser source combined into a single output port, 850-1550nm power meter, Integrated VFL, SC adapter for power meter and a set of 50/125 SC-SC Test Reference Cords | ||||
DTX-GFM2 Gold Support:
| |||||
| DTX-SFM2 | DTX Singlemode Fiber Modules - Includes two modules (one for Main and one for Smart Remote). each module contains 1310 nm and 1550 nm laser light source combined into single output port, 850-1550 nm power meter, integrated VFL, SC adapter for power meter and Singlemode SC-SC Test Reference Cords | ||||
DTX-SFM2 Gold Support:
| |||||
| DTX-FTK | DTX Fiber Test Kit includes DTX-FOM fiber optic meter, SimpliFiber 850 nm and 1300 nm LED optical source with carrying case and multiple language user guides | ||||
DTX-FTK Gold Support:
| |||||
| DTX-OTDR/LL-KIT | DTX Compact OTDR & Loss Length Kit: Includes Sets of Multimode DTX MFM2 and Singlemode DTX SFM2 Fiber (loss/length) modules, DTX Compact OTDR Module, launch fibers, accessories and carrying case | ||||
DTX-OTDR/LL-KIT Gold Support:
| |||||
| DTX-OTDR-KIT | DTX OTDR Add-on Kit: Includes DTX Compact OTDR Module, launch fibers, accessories and carrying case | ||||
DTX-OTDR-KIT Gold Support:
| |||||
| NFA-SC | Set of two SC Adapters for DTX-xFM2 power meter port. | ||||
| NFA-LC | Set of two LC Adapters for DTX-xFM2 power meter port. | ||||
| NFA-ST | Set of two ST Adapters for DTX-xFM2 power meter port. | ||||
| NFA-FC | FC Test Adapters, Set of two | ||||
| NFB1/2-LC/ST | A kit containing the Test Reference Cords sets NFK1-DPLX-LC, NFK1-DPLX-ST, NFK2-DPLX-LC, NFK2-DPLX-ST, LC and ST adapters for the power meter and 62.5/125 and 50/125 | ||||
| NFK1-DPLX-SC | Duplex MM 62.5 μm TRC for SC Adapter, Set of 2 | ||||
| NFK1-DPLX-LC | Duplex MM 62.5 | ||||
| NFK1-DPLX-ST | Duplex MM 62.5 | ||||
| NFK1-DPLX-FC | Duplex MM 62.5 | ||||
| NFK2-DPLX-SC | Duplex MM 50 | ||||
| NFK2-DPLX-LC | Duplex MM 50 | ||||
| NFK2-DPLX-ST | Duplex MM 50 | ||||
| NFK2-DPLX-FC | Duplex MM 50 | ||||
| NFK3-DPLX-SC | Duplex SM TRC for SC Adapter, Set of 2 | ||||
| NFK3-DPLX-LC | Duplex SM TRC for LC Adapter, Set of 2 | ||||
| NFK3-DPLX-ST | Duplex SM TRC for ST Adapter, Set of 2 | ||||
| NFK3-DPLX-FC | Duplex SM TRC for FC Adapter, Set of 2 | ||||
| NFK1-LC | LC Accessory Kit, 62.5 | ||||
| NFK1-MANDREL-KIT | Multimode Fiber Mandrel kit containing two red mandrels for 50/125 µm cable and two gray mandrels for 62.5/125 µm cable | ||||
| NF-MANDREL-50 | Multimode Fiber Mandrel for 50/125 | ||||
| NF-MANDREL-625 | Multimode Fiber Mandrel for 62.5/125 | ||||
| NFC-Kit-Case | Fiber Optic Cleaning Kit. | ||||
| NF400 | Fiber Accessories Carrying Case | ||||
| DTX-FIBER-CASE | Protective carrying case for DTX Compact OTDR Kits | ||||
| DTX-FBRCSE | Carry case for DTX-xFM or DTX-xFM2 Fiber Loss Test Modules with storage space for Test Reference Cords and fiber connector adapters | ||||
| Personality Modules | |||||
| DSP-PM19B | SYSTIMAX® VisiPatch® 360 (T568B) Personality Module | ||||
| DSP-PM19A | SYSTIMAX® VisiPatch® 360 (T568A) Personality Module | ||||
| DSP-PM17B | TYCO/AMP 610XC CONNECTOR (T568B) Personality Module | ||||
| DSP-PM17A | TYCO/AMP 610XC CONNECTOR (T568A) Personality Module | ||||
| DSP-PM16B | LEVITON 110 (T568B) Personality Module | ||||
| DSP-PM16A | LEVITON 110 (T568A) Personality Module | ||||
| DSP-PM15B | ADC/KRONE HIGHBAND (T568B) Personality Module | ||||
| DSP-PM15A | ADC/KRONE HIGHBAND (T568A) Personality Module | ||||
| DSP-PM14B | ADC/KRONE ULTIM8 (T568B) Personality Module | ||||
| DSP-PM14A | ADC/KRONE ULTIM8 (T568A) Personality Module | ||||
| DSP-PM13B | SIEMON S210 (T568B) Personality Module | ||||
| DSP-PM13A | SIEMON S210 (T568A) Personality Module | ||||
| DSP-PM12B | PANDUIT GIGAPUNCH (T568B) Personality Module | ||||
| DSP-PM11B | Gerard Industries CP GigaPro (T568B) Personality Module | ||||
| DSP-PM11A | Gerard Industries CP GigaPro (T568A) Personality Module | ||||
| DSP-PM10B | SYSTIMAX® 110 (T568B) Personality Module | ||||
| DSP-PM10A | SYSTIMAX® 110 (T568A) Personality Module | ||||
| DTX-EFM2 | Set of two DTX Encircled Flux Multimode Fiber Modules, each incorporating: 850 nm and 1300 nm LED sources combined into a single output port Set of Encircled Flux compliant test reference cords(EF-TRC) 850/1300/1310/1550 nm power meter Integrated VFL See Photo | ||||
DTX-EFM2 Gold Support:
| |||||
Cable Types Standard Link Interface Adapters | Shielded and unshielded Twisted Pair (STP, FTP, SSTP and UTP) LAN cabling:
|
Test Standards |
|
Speed of Autotest | Full 2-way Autotest of Category 6 Twisted-Pair links in 9 seconds |
Supported Tests Parameters | (The selected test standard determines the test parameters and the frequency range of the tests) Wire Map |
Cable Tone Generator | Generates tones that can be detected by a tone probe such as a Fluke Networks IntelliTone probe. The tones are generated on all pairs. Frequency range on all pairs. Frequency range of tones: 440 Hz to 831 Hz |
Display | 3.7 in (9.4 cm) diagonal, 240 dots wide by 320 dots high, passive color, transmissive LCD with backlight. |
Input Protection | Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage. |
Case | High impact plastic with shock absorbing overmold |
Dimensions | Main unit and Smart Remote: 8.5 in x 4.4 in x 2.4 in (21.6 cm x 11.2 cm x 6cm), nominal |
Weight | 2.4 lb (1.1 kg), nominal (without adapter or module) |
Operating Temperature | 32°F to 104°F (0°C to 40°C) |
Storage Temperature | -4°F to 104°F (-20°C to 60°C) |
Operating relative humidity (% RH without condensation) | 32°F to 95 °F (0°C to 35°C): 0 % to 90 % 95°F to 113°F (35°C to 45°C): 0 % to 70 % |
Vibration | Random, 2 g, 5 Hz -500 Hz |
Shock | 1 m drop test with and without module and adapter attached |
Safety | CSA C22.2 No. 1010.1: 1992 EN 61010-1 1st Edition Amendments 1, 2 |
Pollution degree | Pollution Degree 2 as defined in IEC 60664 and applied to IEC 60950 "Safety of Information Technology Equipment, 1999" |
Altitude | Operating: 4000 m; Storage: 12000 m |
EMC | EN 61326-1 |
Power | Main unit and remote: Lithium-ion battery pack, 7.4 V, 4000 mAh
|
Languages Supported | English, French, German, Spanish, Portuguese, Italian, Japanese, and Simplified Chinese, Traditional Chinese, Korean, Russian, Czech, Polish, Swedish, Hungarian. |
Calibration | Service center calibration period is 1 year |
Performance Specifications | Note: all specifications for tests on twisted-pair cabling apply to 100 Ω cable. Contact Fluke Networks for information on measurement performance for cable with a different impedance. |
Baseline accuracy | Exceeds the requirements of Level IV as in IEC 61935-1/Ed. 3 |
Category 6A/Class EA link test modes (and lower link categories) | DTX CableAnalyzer far exceeds Level III requirements of ANSI/TIA-1152 and IEC 61935-1/Ed.3 |
Class F link test modes | DTX-1800 meets or exceeds the requirements of Level IV as in IEC 61935-1/Ed. 3. |
Length for Twisted Pair Cabling | (Length specs do not include the uncertainty of the cable's NVP Value) |
Parameter | Single-ended Test |
Range | 800 m (2600 ft) - Single-ended Test |
Resolution | 0.1 m or 1 ft - Single-ended Test |
Accuracy | ± (1m 4%) - Single-ended Test |
Delay Skew | |
Parameter | Twisted Pair Cabling |
Range | 0 ns to 100 ns |
Resolution | 1 ns |
Accuracy | ± 10 ns |
DC Loop Resistance Test | |
Parameter | Twisted Pair Cabling |
Range | O Ω to 53Ω |
Resolution | 0.1 Ω |
Accuracy | ± (1 Ω 1%) |
Overload Recovery Time | Less than 10 minutes to rated accuracy following over-voltage. Referencing is required after repeated or prolonged over-voltage. |
| Title/Description | Download | |
Fiber Troubleshooting Quick-Reference Guide
Test and Troubleshooting Guide for Optical Fiber Cabling and DataCommunications | Download PDF (2.71 MB) | |
Industrial Networks Troubleshooting Guide
Troubleshooting Guide for Industrial Ethernet and Other Network Protocols | Download PDF (6.95 MB) | |
DTX Copper Cable Troubleshooting Handbook
DTX Copper Cable Troubleshooting Handbook | Download PDF (4.61 MB) | |
Optical Fiber Test and Troubleshooting Solutions
A look at Fluke Networks' portfolio of fiber solutions. Discover which fiber test tools you need in your tool kit to best tackle any job. | Download PDF (2.31 MB) | |
Copper Cabling Troubleshooting Handbook
Copper Cabling Troubleshooting Handbook | Download PDF (1.15 MB) | |
DTX CableAnalyzer Brochure
DTX CableAnalyzer Brochure | Download PDF (2.39 MB) | |
DTX CableAnalyzer Accessories Brochure
DTX CableAnalyzer Accessories Brochure | Download PDF (5.48 MB) |
| Title/Description | Download | |
DTX CableAnalyzer Gold Benefits/value Flyer - US
DTX CableAnalyzer Gold Benefits/value Flyer | Download PDF (749 KB) | |
LinkWare Data Sheet
LinkWare Data Sheet | Download PDF (901 KB) | |
DTX Compact OTDR Datasheet
DTX Compact OTDR Datasheet | Download PDF (2.1 MB) | |
Patch Cord Test Adapter Data Sheet
Patch Cord Test Adapter Data Sheet | Download PDF (372 KB) | |
DTX Specification/Ordering Guide
DTX Specification/Ordering Guide | Download PDF (125 KB) | |
DTX M12 Channel Adapters Datasheet
DTX M12 Channel Adapters Datasheet | Download PDF (1.01 MB) | |
DTX Network Service Module Data Sheet
DTX Network Service Module Data Sheet | Download PDF (542 KB) | |
DTX Fiber Extended Specifications Guide
DTX Fiber Extended Specifications Guide | Download PDF (450 KB) | |
DTX Linkware Report
DTX Linkware Report | Download PDF (99 KB) | |
DTX AC Wiremap Data Sheet
Gives overview of DTX AC Wiremap features and benefits | Download PDF (721 KB) | |
DTX Network Service LinkWare Report
DTX Network Service LinkWare Report | Download PDF (105 KB) | |
10 Gig Kit Data Sheet
10 Gig Kit Data Sheet | Download PDF (1.98 MB) | |
DTX Fiber Test Kit Data Sheet
DTX Fiber Test Kit Data Sheet | Download PDF (797 KB) |
| Title/Description | Download | |
Fluke Networks' Solution Catalog
64 page guide to selection and ordering Fluke Networks' Solutions and Products | Download PDF (6.39 MB) |
| Title/Description | Download | |
How to get the most out of cable test reports Application Note
Learn how test results analysis software helps you to quickly see the true performance of the entire cabling plant and spot any anomalies or inconsistencies. | Download PDF (166 KB) | |
Guide to Choosing the Right Cable Test Tool to Meet Your Testing Needs Application Note
Learn the distinction between the three cable test tool categories (verification, qualification and certification) so you can choose the tester that truly meets your testing needs. | Download PDF (383 KB) | |
Certification Testing of Twisted Pair Patch Cords
Certification Testing of Twisted Pair Patch Cords | Download PDF (806 KB) | |
Encircled Flux Application Note
How will Encircled Flux launch conditions improve my link loss measurements? | Download PDF (1.13 MB) | |
Verifying Network Service Availability Application Note
See how to verify and document the availability of network services over a cabling link with the DTX CableAnalzyer. | Download PDF (901 KB) | |
Hope is Not a Warranty Application Note
A warranty that is not based on proper certification testing documented by electronically retrievable test results only provides hope, not a solid assurance. | Download PDF (1.41 MB) | |
DTX 10 Gig Diagnostics Application Note
Find out what you can do when cabling links fail compliance with the 10GBASE-T standard. | Download PDF (478 KB) | |
Testing LC Fiber Optic Links Application Note
Learn about LC testing with DSP-4000 Series FTAs and DTX-xFM | Download PDF (125 KB) | |
Testing MT-RJ Fiber Optic Links Application Note
Learn about modified Method B for fiber loss certification. | Download PDF (134 KB) | |
Testing VF-45 Fiber Optic Links Application Note
Learn about modified Method B for fiber loss certification. | Download PDF (126 KB) |
| Title/Description | Download | |
How to Certify or Re-certify Twisted-Pair Cabling for 10Gb/s Ethernet
Learn how new installation and testing guidelines help combat Alien Crosstalk. | Download PDF (1.16 MB) | |
Finding your way in the maze of industrial Ethernet standards
Finding your way in the maze of industrial Ethernet standards | Download PDF (447 KB) | |
Ethernet In A Harsh Environment - White Paper
Whitepaper that discusses the unique issues that can arise when you deploy Ethernet in an industrial environment, and how to avoid production downtime caused by these issues. | Download PDF (62 KB) | |
Whitepaper: Troubleshooting Your Industrial Network
Whitepaper: Troubleshooting Your Industrial Network | Download PDF (248 KB) | |
How to cable 802.11n Wireless Access Points
This paper discusses the impact 802.11n will have on cabling as well as what installers and enterprises should do to address them. | Download PDF (366 KB) | |
White Paper: Benefits Of Industrial Standards In Industrial Ethernet Component Selection
The Role Standards Play in Selecting Industrial Ethernet Components | Download PDF (71 KB) | |
Best Practices for Fiber Optic Installation Start with Inspection
This white paper will help you understand what to look for and when, how to inspect and clean and best practices for installation. | Download PDF (378 KB) | |
Datacenter Virtualization White Paper
Connectivity in the Virtualized Datacenter: How to Ensure Next-Generation Services | Download PDF (1.92 MB) | |
White Paper: The High Cost of A Low-Cost Cable Certification Tester
The myriad of high hidden costs you may encounter when using a “low-cost” tester. | Download PDF (788 KB) | |
Certifying Power Over Ethernet To Ensure Service Success
Certifying Power Over Ethernet To Ensure Service Success | Download PDF (601 KB) | |
Six Reasons Certification Is Essential White Paper
This paper identifies the specific benefits afforded by cable certification and how much it pays back to the network owner. | Download PDF (102 KB) | |
Fiber Test Best Practices: Tier 1 Certification
Fiber Test Best Practices: Tier 1 Certification | Download PDF (194 KB) | |
Testing Power Over Ethernet (PoE) Enabled Systems Whitepaper
Understand the potential impacts on the certification and testing process. | Download PDF (232 KB) | |
The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges White Paper
This paper revisits the Permanent Link test model, highlights its benefits, and examines its impact on the operations and performance requirements of field test equipment. | Download PDF (440 KB) |
| Title/Description | Download | |
Fiber Test And Troubleshooting Instruments Comparison Guide
Fiber Test And Troubleshooting Instruments Comparison Guide | Download PDF (362 KB) |
| Title/Description | Demo | |
DTX CableAnalyzer Virtual Demo | View Demo | |
DTX 10 Gig Over Copper Cable Test Solution Virtual Demo | View Demo |
Gold Support for your DTX CableAnalyzer allows you to make the most of your DTX CableAnalyzer purchase while ensuring a higher return on your investment.
You will minimize your downtime, receive faster trouble resolution and have total access to all support resources.
What do you get with Gold Support for your DTX CableAnalyzer and DTX Fiber modules?
Annual Calibration and Factory Refresh - ISO 9001 standards compliance requires annual unit calibration. Keeping your DTX CableAnalyzer and Fiber modules calibrated is critical to ensure accuracy when testing fiber networks. Our calibration processes are ISO-9001 controlled and designed to certify that your DTX and Fiber modules meet all published specifications. To receive a loaner unit during calibration (available in most regions), we recommend you schedule your appointment 6 weeks in advance of your required calibration date. If a loaner is not required or calibration cannot be scheduled in advance, Gold customers may opt to instead receive a shipping waybill and calibrations will receive priority turnaround. Typical turnaround time for a calibration is 5 working days. Your DTX unit and Fiber modules will be precisely calibrated to factory specifications (calibration certificate provide - calibration traceable with data available for extra charge), repaired as necessary with genuine OEM repair parts, upgraded with all of the latest software and firmware then cleaned and performance verified. In addition, all accessories that came with your DTX will be tested and replaced if faulty or defective.
Repairs and loaner equipment - If your DTX or Fiber Modules should fail, we'll deliver a loaner unit via next-day delivery to keep you up and running. We'll repair your DTX or Fiber modules and replace defective accessories that came with your unit at no charge, with "first on bench" priority, and return it to you - all shipping paid by Fluke Networks.
Accessory Replacement - Some accessories are essential to testing and certifying cable. If any accessory that comes with your DTX model are qualified as defective or faulty by our technical assistance center, it will be replaced free of charge. Universal Permanent Link Adapters and Modules are limited to replacement of one set per year, provided they have met the aforementioned criteria.
Covered accessories include:
• Batteries • Channel Adapter • DSP-PM06 Personality Modules -(1per year)
• Chargers • Cables • Carrying cases em>• Link Adapter - (1 per year)
Gold Lifetime BuyBack Guarantee - Buy the tools you need now knowing that Fluke Networks will buy it back when it’s time for a new one. Get 100% cash back within 30 days, 60% within 1 year, and 15% after a year for the life of your tester covered by Gold. (Full terms and conditions can be found at www.flukenetworks.com/GoldBuyBack.) (Currently not available within Asia)
Access to live 24 x 7 technical support - Extend the expertise of your staff. Gold Support includes priority access to our world-class Technical Assistance Center (TAC). Our centers in Seattle, WA and Eindhoven, NL employ a full staff of highly trained technical experts that are on call, including weekends and through the night, to answer complex troubleshooting questions, including GOLD only services such as: Test set-up and instrument configuration, Fiber testing and reference setting, Test results interpretation, including trace results analysis. Let us help you get the most out of your DTX and Fiber modules and understand the results you are seeing.
DTX Gold Support Members Training - Online training that can be utilized without having to take your staff out of the field can be a valuable tool. Gold Support Members have several exclusive on-line training modules available.
Unlimited access to our Knowledge Base - You’ll have an open door to valuable proprietary information we’ve gathered from helping customers over the years. It also includes helpful technical articles written by our experts.
Member Only promotions - Your membership qualifies you for “Members Only” promotions and programs. This includes product discounts, access to reconditioned equipment at special prices and other incredible values.
Ensure that you are getting the most out of your DTX CableAnalyzer and Fiber Modules with Gold Support Services. Gold Support must be purchased for the Mainframe and Fiber Modules for complete coverage.
900 MHz and Class F (Cat 7) manufacturer’s endorsements
The top-of-the-line DTX CableAnalyzer — the DTX-1800 — supports testing up to 900 MHz. This extended bandwidth supports the ISO Class F links, as well as emerging standards like 10 Gigabit Ethernet over twisted-pair cabling. It also enables you to certify links for other applications, such as video distribution over twisted pair cabling. No other tester on the market gives you this kind of future-proof investment while meeting current Cat 5e/6 specifications.
Manufacturers are integral to the testing decisions you make. To support their warranties, your certification tests must be performed with approved tools so you can ensure your customers' complete satisfaction.
Fluke Networks has subjected the DTX Series testers to rigorous testing in the labs of leading wiring manufacturers. Click on the vendor logo below to display approval letter.
These Class F (Cat 7) certification endorsements complement the endorsements for certification of Cat 5e (Class D) and Cat 6 (Class E) links and channels. Click on the vendor name to see approval letter.
| AMP Connect | BKS | CTI Netzwerksysteme |
| Corning | Datwyler | Kerpen |
| Siemon |