Pro3000™ Analog Tone and Probe Specifications |
 |
|
Pro3000 Analog Toner Specifications |
|
User interface |
Slide switch selects Continuity or Tone ModePush button switch selects SOLID, ALT or OFFTone mode LEDContinuity/Polarity LED |
|
Solid Frequency |
1000 Hz nominal |
|
Alternating Frequency |
1000/1500 Hz nominal |
|
Over Voltage Protection |
60 Vdc in Toner/Polarity Mode |
|
Output Power in Tone Mode |
8 dbm into 600 ohms |
|
Output Voltage Level in Continuity Mode |
8 Vdc with fresh battery |
|
Battery |
9V alkaline |
|
Temperature |
Operating: -20˚ C to 60˚ C, Storage: -40˚ C to 70˚ C |
|
Case dimensions |
2.7 in. x 2.4 in. x 1.4 in. (6.9 cm x 6.1 cm x 3.6 cm) |
|
Pro3000 Analog Probe Specifications |
|
User interface |
ON/OFF pushbuttonVolume dialReplaceable tip3.5 mm earphone jack |
|
Battery |
9V alkaline |
|
Temperature |
Operating: -20˚ C to 60˚ C, Storage: -40˚ C to 70˚ C |
|
Case dimensions |
9.8 in. x 1.6 in. x 1.3 in. (24.9 cm x 4.1 cm x 3.3 cm) |
|
Pro3000 Analog Toner Specifications |
|
User interface |
Slide switch selects Continuity or Tone ModePush button switch selects SOLID, ALT or OFFTone mode LEDContinuity/Polarity LED |
|
Solid Frequency |
1000 Hz nominal |
|
Alternating Frequency |
1000/1500 Hz nominal |
|
Over Voltage Protection |
60 Vdc in Toner/Polarity Mode |
|
Output Power in Tone Mode |
8 dbm into 600 ohms |
|
Output Voltage Level in Continuity Mode |
8 Vdc with fresh battery |
|
Battery |
9V alkaline |
|
Temperature |
Operating: -20˚ C to 60˚ C, Storage: -40˚ C to 70˚ C |
|
Case dimensions |
2.7 in. x 2.4 in. x 1.4 in. (6.9 cm x 6.1 cm x 3.6 cm) |
|
Pro3000 Analog Probe Specifications |
|
User interface |
ON/OFF pushbuttonVolume dialReplaceable tip3.5 mm earphone jack |
|
Battery |
9V alkaline |
|
Temperature |
Operating: -20˚ C to 60˚ C, Storage: -40˚ C to 70˚ C |
|
Case dimensions |
9.8 in. x 1.6 in. x 1.3 in. (24.9 cm x 4.1 cm x 3.3 cm) |
|
 |
|
 |

|