Analysis and Monitoring

 

OptiView® Link Analyzer

PRODUCT FINDER
We’ll help you determine the right tool for the job. Try our online tool...

OptiView® Link Analyzer
Specifications

Physical Specifications

Number of Media Module(s)

two

Memory

128 MB per media module (256MB when used in synchronized mode)

Hard Drive

80 Gigabyte IDE included with OPV-LA/HD

Analyzer ports on Media Module

Removable 1000 BASE-SX GBIC, Duplex SC-type connector, multimode and 10/100 Mbps RJ-45

Analyzer Port LEDs

10/100 link LED Gigabit link LED

Dimension

3.5 x 13.5 x 14.5 in (8.9 x 34.3 x 36.8 cm)

Weight

18 lbs (8.2kg)

Power Consumption

120 watts

Fuse Protection

2.5A @ 250V

Input Voltage Range

90-264V

Input Frequency

48-62 Hz



Traffic Monitoring Capability

Buffer Size

128 MB per module

Network Statistics

All

Packet Decode Summary

N/A

Sync View, Full-Duplex

Yes

Packet Slicing

32, 64, 128 byte, full packet options

Monitor Filter Uses

capture filter



RMON Capability

RMON 1 Groups Supported

  • Ethernet Statistics group
  • History Control group
  • Ethernet History group
  • Alarm group
  • Event group
  • Host group
  • Host TopN group
  • Matrix group

RMON 2 Groups Supported

  • Protocol Directory group
  • Protocol Distribution group
  • Address Map group
  • Network Layer Host group
  • Network Layer Matrix group
  • Application Layer Host group
  • Application Layer Matrix group
  • User History group
  • Probe Config group


Traffic Capture Capability

Capture Performance

@10 Mbps: 14,880 pps
@100 Mbps: >148,809 pps
@1 Gbps: >1,488,090 pps

Capture Packets Filter

Hardware-based, up to 16 filters may be applied on a single packet without affecting performance.

Number of custom counters supported

8

Packet Slicing for capture

32, 64, 128 bytes, full packet options

Timestamp Resolution

25 nanoseconds



Traffic Generation Capability

Load Specification

<1 to 100%, up to 5-6 min

Iterations: number of times a group of frames is transmitted

1 to 100,000,000 or continuous

Pre-defined protocol templates

802.1D
ARP
ISL
AppleTalk® Echo Request (ASP, ATP, PAP)
TCP Application layer packets (FTP, HTTP, NetBIOS®, SNTP, SMTP) Netware packets (NCP, IPX®, SAP, NetBIOS) Ethernet DEC Request SVS ID (DNA, LAC, NSP) IP SNAP (TCP, UDP)
IP Network layer (ICMP, OSPF)
Note: User can create custom templates.

Message length range includes FCS

8 to 1,518 bytes using Packet Editor. A packet of up to 5000 bytes may be created using the Packet Editor.

Frame Copy

Copy from another message. Copy from capture buffer.

Frame Formats

Ethernet IEEE 802.3

Number of user-defined bytes per message in address fields

All can be user defined

Pre-defined data patterns for data field bytes 15 to 78 of message

As part of the Traffic Generation Option, Fluke Networks supports:

  1. selection among several data streams
  2. user entered data
  3. packet data incrementing sequentially from an offset (n, n@1, n@2.... )

Frame padding selected from these options

User-defined: any one byte value 0x00 to 1xFF
Incremental: pattern increments from 0x00 to oxFF, then repeats Random: data pattern is andom after first 12 bytes

FCS Selection

Good: automatically calculated
Bad: use-definable

Errors

Runts, Jabbers, Bad FCS

Ethernet Interface gap (minimum)

8.8 ms @10 Mbps
0.88 ms @ 100 Mbps
0.15 ms @ 1000 Mbps

Ethernet Percent Utilization (maximum)

Frame Size 10/100 Mbps 1G Mbps
19 88% 70%
64 94% 75%
1518 99% 98%
3898 100% 99%






POPULAR LINKS

LEARN ABOUT
Network Analysis
Network Monitoring
Application Performance Management
Troubleshooting LANs

Go to Features