| General Specifications |
| Weight,with battery |
0.86 kg (1.9 lb) |
| Dimensions |
19.1 x 15.2 x 4.4 cm (7.5 x 6.0 x 1.75 in) |
| Display |
LCD touch screen, 640 x 480 pixels, TFT (active) color panel, touch pad |
| LED indicators |
6 (including power LED) |
| Carrying Case |
Rugged carrying case with two removable pockets, camcorder strap and adjustable strand hook |
|
| Power |
| Battery |
Lithium Ion 7.2V DC (nominal), 4.2Ah, removable/rechargeable |
| Battery life |
4 hour typical, 10 hour in standby mode |
| External AC adapter/battery charger |
AC input: 90 to 264 V ac, 48 to 62 Hz; 1.5 A |
| |
DC output: 15 V dc, 1.2 A (isolated output) |
| Auto Charger |
12V “cigarette lighter” charger with 6 foot (1.8 m) fully extended coiled cord and LED power indication |
|
| Ports |
| Communication and accessory ports |
1 USB (supports out-of-band NIC for remote control), 1 PCMCIA/Cardbus (PC Card type II), 1 SFP cage, 1 CompactFlash (Card Type I/II), 1 DB-9 serial, headphone jack, microphone jack, Kensington lock receptacle |
| RJ-45 / Copper Port |
RJ-45 10/100/1000BASE-T Ethernet |
| Fiber Port |
Small Form-factor Pluggable (SFP) in accordance with MSA |
| Supported SFP Modules |
1000BASE- LX, SX, ZX, BX, 100BASEFX |
| SFP Connector |
Duplex LC |
|
| Environmental and safety |
| Operating Temperature |
0° to +50°C (32° to 122°F) with up to 95% relative humidity |
| Battery Charging |
10° to +40°C (50° to 104°F) with up to 95% relative humidity |
| Temperature |
|
| Storage temperature |
-20° to +60°C (-4° to 140°F) |
| Shock and vibration |
Meets requirements of MIL-PRF-28800F for Class 3 equipment |
| Safety |
CSA Canada and United States, CE, FCC Part 15 Class A, C-TICK N10140; UL and CSA approvals for universal AC adapter. EMC Complies with EN61326, Class A, Criteria C |
|
| Copper media |
| Cable types |
Unshielded twisted pair LAN cables (100 and 120 Ohm UTP) |
| |
Foil-screened twisted pair LAN cables (100 and 120 Ohm ScTP) |
| Cable length |
1 to 305 m (3 to 1000 ft), accuracy dependent upon the cable type selected |
| Length resolution |
± [5% of reading + 1 m (3 ft)], with open, shorted, with wire map adapter, or terminated with reflection = 20% |
| Receive level |
100 to 5000 mVp-p |
| Datalink signal |
500 to 4000 mVp-p |
| Measuring terminated cables |
The Cable Verification feature tests the individual twisted-pairs of a cable that are terminated into most equipment vendor's Ethernet ports such as on a hub, switch or NIC. All cable tests other than WireView wire map and office locator ID are operational in the presence of datalink signal. |
| Wiremapper/office locator compatibility |
Detects combinations of shorts, opens, and connector miswires. Compatible with Fluke Networks WireView wire map adapter/office locator. |
| Fault tolerance |
The RJ-45 Ethernet connection on the analyzer is designed to withstand a maximum of 100 volts. |
|
| Fiber optic power measurements |
| Receive Input Power, Transmit Output Power, Temperature, Voltage, TX Bias Current |
Real time access to digital diagnostic monitoring of SFP operating parameters in accordance with the SFP Multi Source Agreement (MSA) and SFF-8472. |
|
| ProVision™ Tests |
| Compatible remote devices |
MetroScope, LinkReflector, EtherScope, Physical Loopback, 802.3ah Devices |
| Test Configuration |
Each test may be made up of an unlimited number of suites which run sequentially. Each suite may measure a maximum of eight streams total (including upstream and downstream) from one to four MetroScope units or a maximum of four streams (roundtrip) from one to four reflectors. |
| Test Duration |
Each suite can run for any length of time from 1s to 24h. Suites may be run sequentially for virtually unlimited test lengths. |
| Tests |
Throughput, Latency, Jitter, Loss/BERT, measured in parallel |
| Application port |
User defined, per stream |
| Frame content |
All 0s, all 1s, alternating 1s and 0s, Pseudo Random Bit Sequence (PRBS), Incrementing Byte, HFPAT, LFPAT, MFPAT, LCRPAT, SCRPAT |
| Frame size |
48, 64, 128, 256, 512, 1024, 1280, 1518, 2024, RFC-2544 sweep, Jumbo sweep, or user-defined including baby jumbo sizes up to 2024 |
| Rate (bps) |
Up to 1000 MBps (selectable per stream) |
| 802.1Q settings |
VLAN Id, QoS with CoS and ToS , QinQ VLAN Id, priority for each individual stream or all streams. Programmable TPID, DEI, CFI and VID for all streams. |
| IP TOS settings |
IP Precedence/TOS parameter, DiffServe Code Point |
| Pass/Fail Limits |
Throughput (separate upstream and downstream), Latency, Jitter, Loss/BERT |
| Summary Display |
Summary matrix of all streams and all measurements; IP/Mac addresses, VLANPriority/TOS, status,Tx and Rx rates in bps and fps, frames sent and lost, loss ratio, errored intervals; current, average, maximum latency and jitter. |
| Detailed Display |
Individual measurements may be shown in tabular (by frame size), graphical (by frame size) or trending (by current interfal or total test duration for all frame sizes). |
| Frame Loss Statistics |
Total, current, and maximum for: frames sent and lost, loss ratio, BER, errored intervals, severely errored intervals |
| Data Export |
Throughput, Frames Sent/Received, Loss, Delay and Jitter test results for each stream are time stamped and saved to the CD card once per measurement interval for the duration of the test. |
|
| RFC 2544 Tests |
| Compatible remote devices |
MetroScope, LinkReflector, EtherScope Layer 1 Loopback, 802.3ah Devices |
| RFC-2544 Compliant Tests |
Throughput, Latency, Frame Loss, Back-to-Back |
| Additional Performance Tests |
Jitter, FrameBERT |
| Frame content |
All 0s, all 1s, alternating 1s and 0s, Pseudo Random Bit Sequence (PRBS), Incrementing Byte , HFPAT, LFPAT, MFPAT, LCRPAT, SCRPAT |
| Frame size |
48, 64, 128, 256, 512, 1024, 1280, 1518, RFC-2544 sweep, Jumbo sweep, or user-defined including baby jumbo sizes up to 2024 |
| Application port |
User defined |
| Rate (bps) |
Up to 1000 Mbps |
| 802.1Q settings |
VLAN Id, priority |
| IP TOS settings |
IP Precedence/TOS parameter, DiffServe Code Point |
| Throughput settings |
Duration, maximum rate, measurement accuracy, pass/fail limits |
| Latency settings |
Duration, rate, iterations, pass/fail limits |
| Frame loss settings |
Duration, rate, step size, pass/fail limits |
| Frame loss settings |
Duration, rate, step size, pass fail |
| Back to Back settings |
Min and Max duration, rate, iterations, pass/fail |
| Jitter Settings |
Duration, rate, pass/fail |
| FrameBERT Settings |
Duration, rate, pass/fail |
|
| Traffic generator |
| Traffic type |
Broadcast, multicast or unicast |
| Frame type |
Benign Ethernet, Benign LLC, NetBEUI, Benign IP, IP/ICMP Echo, IP/UDP Echo, IP/UDP Discard, IP/UDP Chargen, IP/UDP NFS, IP/UDP NetBIOS , Layer 1/2/3 BERT |
| Frame size |
48 , 2024 bytes (48,2024) |
| Rate |
Utilization (%): 0.1 – 100, Frames/second: 1 – 1488095 |
| Duration |
Seconds: 1 – continuous, Frames: 1 – continuous |
| FCS Error |
Generates any frame setting with an FCS error |
| Background mode |
May be run concurrent with all other MetroScope tests excluding ProVision and RFC 2544 tests. |
|
| 802.3ah Client |
| Functions |
Remote device discovery, loop-up with 1s keep-alive, loop down. May be run in background while other MS functions are active. |
| Display |
Loopback capability of remote, OAM status OAM mode link status, maximum OAM size, remote state |
|
| IPTV Tests |
| Configuration |
Multicast Group IP, Port Number, join, leave, RTSP URL, setup, play, pause, teardown |
| Results |
IGMP Latency, Total Packets Sent, Connected Time, Received Packet Rate, RFC-4445 MDI Delay Factor and Media Loss Rate for MPEG-2 streams |
|
| Service Performance Tool |
| Category of devices tested |
DHCP Servers, DNS Servers, E-mail Servers (SMTP, POP3), NT File Servers, Web Servers, WINS Servers, User-Defined Servers |
| Test controls |
Iterations, interval |
| Add device by |
IP address or host name (except Web Server where URL added) |
| DHCP Server pass/fail criteria |
Ping response time, server response time |
| DHCP Server BOOTP parameters (optional) |
Subnet mask, domain server, WINS server, NetBIOS scope, POP3 server, router/default gateway, client DNS domain, NetBIOS node type, SMTP server, web server |
| DNS Server pass/fail criteria |
Ping response time, server response time |
| E-mail Server pass/fail criteria |
Ping response time, SMTP SYN/ACK response time, SMTP response time, POP3 SYN/ACK response time, POP3 response time |
| E-mail Server operation modes |
Connect only, log in only, send/receive |
| NT File Server pass/fail criteria |
Ping response time, SYN/ACK response time, connect time |
| NT File Server operation modes |
Server response, read, write/read/delete |
| Web Servers pass/fail criteria |
Web Server name lookup time, ping response time, SYN/ACK response time, first reply time, receive time, receive rate |
| WINS Servers pass/fail criteria |
Ping response time, server response time |
| User-Defined Servers pass/fail criteria |
Ping response time, SYN/ACK response time |
| Results format |
Tabular, graphical, xml-based report |
|
| Wireless LAN Adapter Option |
| Specification compliance |
IEEE 802.11a, 11b, 11g |
| Certifications |
FCC part 15, Telec, CTICK, ETSI, EN301893, EN60950 |
| Interoperability |
WECA Compliant |
| Interface |
32-bit Cardbus |
| Outdoor operating range |
Up to 515 m (1690 ft) |
| Indoor operating range |
Up to 85 m (279 ft) |
| Data rate |
802.11a: up to 54 Mbps, 802.11b: up to 11 Mbps, 802.11g: up to 54 Mbps |
| Output power |
18 dBm peak power |
| Infrastructure mode |
BSS |
| External antenna connector jack |
Hirose MS-147 |
|
| Wireless LAN Directional Antenna |
| Frequency range |
2.4 – 2.5 and 4.9 - 5.9 GHz |
| Minimum gain |
5.0 dBi in the 2.4 GHz band and 7.0 dBi in the 5 GHz band |
| External antenna connector plug |
Hirose MS-147 |
|
| VoIP Phone Option |
| Calling Modes |
SIP Call Manager, Direct IP Address |
| Address Book |
Stores complete settings for up to 99 destinations |
| WAV File Output |
Play 1-30 times or continuous |
| Settings |
Call Manager Registration (Username, Password, Registrar, Proxy); NAT (Server); RTP (Codec and Port); Answer Control (Auto, Wave File, Do Not Disturb); |
| Call Log |
ASCII log of all major call events |
| Measured Results |
Total, current, maximum and minimum for: Frames Received and Dropped, MOS, R-Factor, Latency |
| Trend Graphs |
MOS, R-Factor, Latency Graph with user-selectable update interval of 5s, 10s, 1 min, 10 min, 1 hour |
|
| LinkReflector specifications |
| Weight |
10 oz (311 grams) with batteries installed |
| Dimensions |
5.3” h x 3.1” w x 1.3” d (13.46 cm x 7.87 cm x 3.30 cm) |
| Operating Temperature |
10° to +40°C (50° to 104°F) with up to 95% relative humidity |
| Media Access |
10BASE-T, 100BASE-TX, 1000BASE-T (IEEE 802.3), and PoE (IEEE 802.3af) |
| Operating Modes |
Reflect All, Reflect Targeted MAC, Reflect Targeted IP, Reflect Fluke Networks Test Traffic, Reflect Non-Broadcast, Non-Reflecting (Troubleshooting Mode) |
| Address Setting |
Manual or DHCP |
|
| LinkReflector Troubleshooting Mode |
| Cable Tests |
Pair lengths, opens, shorts, splits, crossed, straight through, and cable ID |
| Tone Generator |
IntelliTone digital tone: [500 KHz]; analog tones: [400Hz, 1KHz] |
| Ping |
Automatically pings default router and DNS server; can be configured to ping up to 10 additional devices. |
| 802.1x |
Discovers and gains authentication to 802.1x networks. |
| PoE Detection |
Detects and identifies PoE type. |
| Port Verification |
Displays make, model, address, slot, and port of the nearest LLDP device |
| User Interface (UI) |
Display: black and white, 2” x 1” display, link LED; control: five push-buttons for selection of icons and navigation of menus; power: on/off button |
| Ports |
Test ports: RJ45 ports (2): network test port, loop-back wire map port; Application port: mini-USB, Kensington lock receptacle |
| Power Source |
4 AA batteries or optional Li-ion Battery Pack with AC Charger |
|
 |
|
 |

|