Specifications

General Specifications


Physical


Size: 9.8"H x 5.3"W x 3.2"D (24.9cm x 13.5cm x 8.1cm) Weight: 4 lbs (1.81 kg)

Display: 320 x 240 pixel graphic LCD with backlight and adjustable contrast

LED Indicator: Charging status indicator (side connector panel)

Communication Port: RS-232 PC/Printer port (DB-9)


Power


AC Operation: External AC adapter/charger

Battery Type (installed): Internal removable NiMH rechargeable battery pack

Battery Life: A fully charged battery provides approximately 16 hours of normal use

Battery Recharge Time (in tester): 2 to 3 hours for a fully discharged battery pack


Environmental


Operating Temperature: -4° to 140° F (-20° to 60° C)

Storage Temperature: -40° to 158° F (-40° to 70° C)

Humidity Tolerance (operation without condensation): 95%

Rain Resistance: IEC60529 IP02, International protection water dripping

Vibration: Random, 2 g, 5 Hz to 500 Hz

Shock: 1 Meter Drop Test

Altitude: 4500 m (15,000 ft)


Regulator Compliance


Safety: CSA C22.2 No.1010.1

CE: EN 61326 Emissions and Immunity CLASS A; EN 61010-1 2nd ammendment



Basic CopperPro


AC Voltage


0 to 250V (1% ± 0.5V accuracy)


DC Voltage (RIN=100 kohms or 10 Mohms)


Range: 0 to 150V (1% ± 0.5V accuracy); 150 to 300V (2% accuracy)


DC Loop Current (430 ohms)


0 to 100 mA (2% ± 0.3 mA accuracy)


Resistance (shorts & grounds)


0 to 100 ohms (0.1% ± 0.10 ohm accuracy)

100 ohms to 1000 kohms (0.2% ± 0.10 ohm accuracy)

4 kohms to 999 Mohms (3% accuracy)


Leakage Stress


2 kohms to 999 Mohms (3% accuracy)


Opens


0 to 3000 ft (1% ± 5 ft accuracy)

3 to 50 kft (3% accuracy)

50 to 80 kft (5% accuracy)


Splits


Range: 0 to 50 kft (Accuracy: 10% of Cable Length)


RFL (RTS = Res. to Strap)


Fault Resistance (Rf): 0 to 30 Mohms

Loop Resistance: 0 to 4000 ohms

Resistance to Fault (@ Rf = 100 kohms): 0 to 100 ohms (0.1% RTS ± 0.10 ohm); 100 ohms to 4 kohm (0.3% RTS ± 0.10 ohm)


Load Coils


0 to 6 (± 1 accuracy)


Tracing Tone


Frequency: 577.5 Hz (0.1% accuracy)

Range: > 15Vp-p (10% accuracy)


VF Noise


Impedance: 600 ohms, Bridged (1% accuracy)

Filters: C, CN, 3k, 15k, Psophometric

Metallic Noise: 0 to 10 dBrn (± 2 dB accuracy); 10 to 100 dBrn (± 1 dB accuracy)

Power Influence: 40 to 120 dBrn (± 2 dB accuracy)


VF Loss


Signal Level: -40 to 10 dBm (± 0.5 dBm accuracy)

Frequency: 100 Hz to 20 kHz (0.1% ± 2 Hz accuracy)


VF Longitudinal Balance (0 to 70 dB ± 2 dB)


Disturbing Frequency: 200 to 2500 Hz (0.1% accuracy)

Impedance: 600 ohms (1% accuracy)

Filters: C, Psophometric


Send VF Tone


Frequency: 100 Hz to 20 kHz (0.1% accuracy)

Amplitude (settable) Range: -20 to 3 dBm

Amplitude Accuracy: ± 0.5 dB (1 dB increments)

Impedance: 600 ohms, 900 ohms (1% accuracy)



CopperPro Wideband Option


WB Noise/Level


Impedance Range: 100 ohms, 135 ohms, Bridged (1% accuracy)

Filters: E, F, G, None

Frequency: 10 kHz to 1200 kHz (0.1% ± 508 Hz accuracy)

Amplitude: -50 to 3 dBm (± 1 dB @ 135 ohms); -90 to -50 dBm (± 3 dB @ 135 ohms)


WB Loss


Impedance: 135 ohms (1% accuracy)

Frequency: 10 kHz to 1200 kHz (0.1% ± 508 Hz accuracy)

Magnitude: 0 to 50 dB (± 1 dB accuracy); 50 to 70 dB (± 2 dB accuracy)


WB Longitudinal Balance (0 to 70 dB; ± 2 dB)


Disturbing Frequency: 10 to 1200 kHz (0.1% accuracy)

Impedance: 100 ohms, 135 ohms (1% accuracy)

Filters: E, F, G, None


Send WB Tone


Frequency: 10 kHz to 1200 kHz (0.1% ± 508 Hz accuracy)

Amplitude (fixed): 0.0 dBm (± 0.5 dB accuracy)

Impedance: 100 ohms, 135 ohms (1% accuracy)


WB Impulse Noise


Impedance Range: 100 ohms, 135 ohms, Bridged (1% accuracy)

Filters: E, F, G, None

Test Time: 1 to 1440 Minutes (1% accuracy)

Impulse Counter: 0 to 9999

Counter Threshold: -50 to 0 dBm (± 1 dB accuracy)


ADSL Auto-Test


Impedance: 100 ohms Noise Filters: E, F, G, None

ADSL Standard: ANSI, Full, G, Lite


Data Rate Prediction


Resolution: 32 kb/s Downstream Rate

Range: 0 to 8192 kb/s

Downstream Rate Accuracy: ± 96 kb/s (3 units of resolution)

Upstream Rate Range: 0 to 1024 kb/s

Upstream Rate Accuracy: ± 64 kb/s (2 units of resolution)



CopperPro TDR Option


Impedance


135 ohms (1% accuracy)


Pulse-width


20, 100, 500, 1000, 2500, 5000 ns (10% ± 5 ns accuracy)


Vop Selection


0.300 to 0.999


Range (Vop=0.64)


30,000 ft (9144m)


Range Selection (Auto.)


10 ft to 48 kft (3 to 14630m)


Horizontal Resolution


0.5 to 156 ft (0.1524 to 47.5m)


Distance to Reflect.


Range: 0 to 30,000 ft (0 to 9144m)

Accuracy: 1% ± Vop Uncertainty


Vertical Gain


Range: 80 dB

Accuracy: 2 dB


Power Filter


5 kHz Highpass


Averaging Filter


4x Waveform Avg.


Input Protection


± 400 V pk






POPULAR LINKS
Training Presentations for the basics of navigating around CopperPro and accessing and managing its User Feature: